mc9s08dz32 Freescale Semiconductor, Inc, mc9s08dz32 Datasheet - Page 207

no-image

mc9s08dz32

Manufacturer Part Number
mc9s08dz32
Description
Hcs08 Microcontrollers 8-bit Can Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc9s08dz32ACLC
Manufacturer:
OMRON
Quantity:
20 000
Part Number:
mc9s08dz32ACLC
Manufacturer:
FREESCALE
Quantity:
4 354
Part Number:
mc9s08dz32ACLC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08dz32ACLC
Manufacturer:
FREESCALE
Quantity:
4 354
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
870
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
5 000
Part Number:
mc9s08dz32ACLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc9s08dz32ACLF
Quantity:
300
Part Number:
mc9s08dz32ACLH
Manufacturer:
FREESCALE
Quantity:
201
11.3.4
Freescale Semiconductor
Reset
BUSY
ARBL
RXAK
Field
IAAS
SRW
IICIF
TCF
7
6
5
4
2
1
0
W
R
IIC Status Register (IICS)
TCF
Transfer Complete Flag. This bit is set on the completion of a byte transfer. This bit is only valid during or
immediately following a transfer to the IIC module or from the IIC module.The TCF bit is cleared by reading the
IICD register in receive mode or writing to the IICD in transmit mode.
0 Transfer in progress
1 Transfer complete
Addressed as a Slave. The IAAS bit is set when the calling address matches the programmed slave address or
when the GCAEN bit is set and a general call is received. Writing the IICC register clears this bit.
0 Not addressed
1 Addressed as a slave
Bus Busy. The BUSY bit indicates the status of the bus regardless of slave or master mode. The BUSY bit is set
when a start signal is detected and cleared when a stop signal is detected.
0 Bus is idle
1 Bus is busy
Arbitration Lost. This bit is set by hardware when the arbitration procedure is lost. The ARBL bit must be cleared
by software by writing a 1 to it.
0 Standard bus operation
1 Loss of arbitration
Slave Read/Write. When addressed as a slave, the SRW bit indicates the value of the R/W command bit of the
calling address sent to the master.
0 Slave receive, master writing to slave
1 Slave transmit, master reading from slave
IIC Interrupt Flag. The IICIF bit is set when an interrupt is pending. This bit must be cleared by software, by writing
a 1 to it in the interrupt routine. One of the following events can set the IICIF bit:
0 No interrupt pending
1 Interrupt pending
Receive Acknowledge. When the RXAK bit is low, it indicates an acknowledge signal has been received after the
completion of one byte of data transmission on the bus. If the RXAK bit is high it means that no acknowledge
signal is detected.
0 Acknowledge received
1 No acknowledge received
1
7
• One byte transfer completes
• Match of slave address to calling address
• Arbitration lost
= Unimplemented or Reserved
IAAS
0
6
Figure 11-6. IIC Status Register (IICS)
MC9S08DZ60 Series Data Sheet, Rev. 3
Table 11-6. IICS Field Descriptions
BUSY
0
5
ARBL
0
4
Description
3
0
0
Chapter 11 Inter-Integrated Circuit (S08IICV2)
SRW
0
2
IICIF
0
1
RXAK
0
0
207