mc9s08dz32 Freescale Semiconductor, Inc, mc9s08dz32 Datasheet - Page 234

no-image

mc9s08dz32

Manufacturer Part Number
mc9s08dz32
Description
Hcs08 Microcontrollers 8-bit Can Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc9s08dz32ACLC
Manufacturer:
OMRON
Quantity:
20 000
Part Number:
mc9s08dz32ACLC
Manufacturer:
FREESCALE
Quantity:
4 354
Part Number:
mc9s08dz32ACLC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08dz32ACLC
Manufacturer:
FREESCALE
Quantity:
4 354
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
870
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
5 000
Part Number:
mc9s08dz32ACLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc9s08dz32ACLF
Quantity:
300
Part Number:
mc9s08dz32ACLH
Manufacturer:
FREESCALE
Quantity:
201
Chapter 12 Freescale’s Controller Area Network (S08MSCANV1)
Read: Anytime
Write: Anytime when not in initialization mode
12.3.8
The CANTARQ register allows abort request of messages queued for transmission.
Read: Anytime
Write: Anytime when not in initialization mode
234
ABTRQ[2:0]
TXEIE[2:0]
Field
Field
2:0
2:0
Reset:
W
R
MSCAN Transmitter Message Abort Request Register (CANTARQ)
Transmitter Empty Interrupt Enable
0 No interrupt request is generated from this event.
1 A transmitter empty (transmit buffer available for transmission) event causes a transmitter empty interrupt
Abort Request — The CPU sets the ABTRQx bit to request that a scheduled message buffer (TXEx = 0) be
aborted. The MSCAN grants the request if the message has not already started transmission, or if the
transmission is not successful (lost arbitration or error). When a message is aborted, the associated TXE (see
Section 12.3.6, “MSCAN Transmitter Flag Register
Section 12.3.9, “MSCAN Transmitter Message Abort Acknowledge Register
interrupt occurs if enabled. The CPU cannot reset ABTRQx. ABTRQx is reset whenever the associated TXE flag
is set.
0 No abort request
1 Abort request pending
Figure 12-12. MSCAN Transmitter Message Abort Request Register (CANTARQ)
request. See
The CANTIER register is held in the reset state when the initialization mode
is active (INITRQ = 1 and INITAK = 1). This register is writable when not
in initialization mode (INITRQ = 0 and INITAK = 0).
The CANTARQ register is held in the reset state when the initialization
mode is active (INITRQ = 1 and INITAK = 1). This register is writable when
not in initialization mode (INITRQ = 0 and INITAK = 0).
0
0
7
= Unimplemented
Section 12.5.2.2, “Transmit
Table 12-13. CANTARQ Register Field Descriptions
Table 12-12. CANTIER Register Field Descriptions
6
0
0
MC9S08DZ60 Series Data Sheet, Rev. 3
0
0
5
Structures” for details.
NOTE
NOTE
4
0
0
Description
Description
(CANTFLG)”) and abort acknowledge flags (ABTAK, see
0
0
3
ABTRQ2
(CANTAAK)”) are set and a transmit
2
0
ABTRQ1
Freescale Semiconductor
0
1
ABTRQ0
0
0