mc9s08dz32 Freescale Semiconductor, Inc, mc9s08dz32 Datasheet - Page 208

no-image

mc9s08dz32

Manufacturer Part Number
mc9s08dz32
Description
Hcs08 Microcontrollers 8-bit Can Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc9s08dz32ACLC
Manufacturer:
OMRON
Quantity:
20 000
Part Number:
mc9s08dz32ACLC
Manufacturer:
FREESCALE
Quantity:
4 354
Part Number:
mc9s08dz32ACLC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08dz32ACLC
Manufacturer:
FREESCALE
Quantity:
4 354
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
870
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
5 000
Part Number:
mc9s08dz32ACLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08dz32ACLF
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc9s08dz32ACLF
Quantity:
300
Part Number:
mc9s08dz32ACLH
Manufacturer:
FREESCALE
Quantity:
201
Chapter 11 Inter-Integrated Circuit (S08IICV2)
11.3.5
In slave mode, the same functions are available after an address match has occurred.
The TX bit in IICC must correctly reflect the desired direction of transfer in master and slave modes for
the transmission to begin. For instance, if the IIC is configured for master transmit but a master receive is
desired, reading the IICD does not initiate the receive.
Reading the IICD returns the last byte received while the IIC is configured in master receive or slave
receive modes. The IICD does not reflect every byte transmitted on the IIC bus, nor can software verify
that a byte has been written to the IICD correctly by reading it back.
In master transmit mode, the first byte of data written to IICD following assertion of MST is used for the
address transfer and should comprise of the calling address (in bit 7 to bit 1) concatenated with the required
R/W bit (in position bit 0).
11.3.6
208
Reset
Reset
Field
DATA
7–0
W
W
R
R
GCAEN
IIC Data I/O Register (IICD)
IIC Control Register 2 (IICC2)
Data — In master transmit mode, when data is written to the IICD, a data transfer is initiated. The most significant
bit is sent first. In master receive mode, reading this register initiates receiving of the next byte of data.
0
0
7
7
When transitioning out of master receive mode, the IIC mode should be
switched before reading the IICD register to prevent an inadvertent
initiation of a master receive data transfer.
= Unimplemented or Reserved
ADEXT
0
0
6
6
Figure 11-8. IIC Control Register (IICC2)
Figure 11-7. IIC Data I/O Register (IICD)
MC9S08DZ60 Series Data Sheet, Rev. 3
Table 11-7. IICD Field Descriptions
0
0
0
5
5
NOTE
0
0
0
4
4
Description
DATA
3
0
3
0
0
AD10
0
0
2
2
Freescale Semiconductor
AD9
0
0
1
1
AD8
0
0
0
0

Related parts for mc9s08dz32