5.10
5.10.1 SINGLE VOLUME CONTROL (SNGVOL)
5.10.2 SOFT RAMP AND ZERO CROSS CONTROL (SZCX)
5.10.3 AUTO-MUTE (AMUTE)
40
Reserved
7
Volume Control (address 0Dh)
Immediate Change
Zero Cross
Soft Ramp
Soft Ramp on Zero Crossing
Default = 0
Function:
Default = 00
00 - Immediate Change
01 - Zero Cross
10 - Soft Ramp
11 - Soft Ramp on Zero Crossings
Function:
Default = 1
0 - Disabled
1 - Enabled
Function:
The individual channel volume levels are independently controlled by their respective Volume Control
registers when this function is disabled. When enabled, the volume on all channels is determined by
the A1 Channel Volume Control register and the other Volume Control registers are ignored.
When Immediate Change is selected all level changes will take effect immediately in one step.
Zero Cross Enable dictates that signal level changes, either by attenuation changes or muting, will
occur on a signal zero crossing to minimize audible artifacts. The requested level change will occur
after a timeout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms at 48 kHz sample
rate) if the signal does not encounter a zero crossing. The zero cross function is independently mon-
itored and implemented for each channel.
Soft Ramp allows level changes, both muting and attenuation, to be implemented by incrementally
ramping, in 1/8 dB steps, from the current level to the new level at a rate of 1 dB per 8 left/right clock
periods.
Soft Ramp and Zero Cross Enable dictates that signal level changes, either by attenuation changes
or muting, will occur in 1/8 dB steps and be implemented on a signal zero crossing. The 1/8 dB level
change will occur after a timeout period between 512 and 1024 sample periods (10.7 ms to 21.3 ms
at 48 kHz sample rate) if the signal does not encounter a zero crossing. The zero cross function is
independently monitored and implemented for each channel.
SNGVOL
6
SZC1
5
SZC0
4
AMUTE
3
MUTE ADC_SP
2
RAMP_UP
1
CS42428
RAMP_DN
0