MM908E624ACDWB/R Motorola, MM908E624ACDWB/R Datasheet - Page 20

no-image

MM908E624ACDWB/R

Manufacturer Part Number
MM908E624ACDWB/R
Description
TRIPLE HIGH-SIDE SWITCH WITH EMBEDDED MCU AND LIN
Manufacturer
Motorola
Datasheet
908E624 ANALOG DIE MODES OF OPERATION
Stop, and Sleep. In Normal mode the device is active and is
operating under normal application conditions. The Stop and
Sleep modes are low-power modes with wake-up
capabilities.
with V
voltage regulator is turned off (V
20
908E624
Functional Description
Functional Device Operation
The 908E624 offers three operating modes: Normal (Run),
In Stop mode the voltage regulator still supplies the MCU
DD
Legend
WD: Watchdog
WD Disabled: Watchdog disabled (WDCONF terminal connected to GND)
WD Trigger: Watchdog is triggered by SPI command
WD Failed: No watchdog trigger or trigger occurs in closed window
Stop Command: Stop command sent via SPI
Sleep Command: Sleep command sent via SPI
Wake-Up: L1 or L2 state change or LIN bus wake-up or SS rising edge
(limited current capability) and in Sleep mode the
Power
Down
Notes:
WD - means Watchdog
WD disabled - means Watchdog disabled (WDCONF terminal connected to GND)
WD trigger – means Watchdog is triggered by SPI command
WD failed – means no Watchdog trigger or trigger occurs in closed window
STOP Command - means STOP command sent via SPI
SLEEP Command - means SLEEP command send via SPI
Wake-Up - means L1 or L2 state change or LIN bus wake up or SS rising edge
Power Up
DD
= 0 V).
Figure 10. Operating Modes and Transitions
FUNCTIONAL DEVICE OPERATION
Reset
Wake-Up (Reset)
Wake-Up (Reset)
OPERATIONAL MODES
V
V
DD
DD
Normal Request Timeout Expired (NR
Low (>NR
LOW (>NR
and VSUV = 0
and LVF = 0
TOUT
Normal Request timeout expired (NR
V
Reset Delay (t
DD
) expired
High and Reset Delay (t
TOUT
interrupt. Wakeup from Sleep mode is done by a reset and
the voltage regulator is turned back on.
MODE1:2 bits in the SPI Control register.
different operating modes and
overview of the operating mode.
V
V
WD Failed
) Expired
DD
DD
V
V
Wake-up from Stop mode is initiated by a wake-up
The selection of the different modes is controlled by the
Figure 10
WD failed
DD
V
V
Sleep
V
DD
High and
DD
DD
Low
Low
DD
Low
Low
Low
Low
RST
) Expired
RST
Sleep Command
describes how transitions are done between the
) expired
SLEEP Command
TOUT
TOUT
)
Analog Integrated Circuit Device Data
)
Request
Normal
Normal
Table
Stop
Freescale Semiconductor
6, page 21, gives an

Related parts for MM908E624ACDWB/R