MM908E625ACDWB/R2 Motorola, MM908E625ACDWB/R2 Datasheet - Page 18

no-image

MM908E625ACDWB/R2

Manufacturer Part Number
MM908E625ACDWB/R2
Description
Integrated Quad Half H-Bridge with Power Supply / Embedded MCU / and LIN Serial Communication
Manufacturer
Motorola
Datasheet
System Wake-Up
bit for this event is set, the interrupt will wake up the
microcontroller as well as the main voltage regulator (MREG)
(Figure
908E625
18
System wake-up can be initiated by any of four events:
• A falling edge on the LIN terminal.
• A wake-up signal from the AWD.
• A logic [1] at Hall-effect sensor input terminal during cyclic
• An LVR condition.
If one of these wake-up events occurs and the interrupt mask
check via AWD.
6).
Figure 6. STOP Mode/Wake-Up Procedure
MREG = Main Voltage
SPI: Reason for
MCU Die
From Reset
(MREG off)
Interrupt?
Interrupt
Initialize
Operate
Operate
Regulator
GS =1
STOP
SPI:
IRQ
Freescale Semiconductor, Inc.
For More Information On This Product,
Analog Die
Wait for Action
STOP MREG
Assert IRQ_A
Hallport
MREG
AWD
Start
LIN
Go to: www.freescale.com
Interrupt Flag Register (IFR)
HPF—Hall-Effect Sensor Input Terminal Flag Bit
change on any enabled Hall-effect sensor input terminal is
detected. Clear HPF by writing a logic [1] to HPF. Reset clears
the HPF bit. Writing a logic [0] to HPF has no effect.
set and a current above the threshold is detected on any
enabled Hall-effect sensor input terminal. Clear HPF by writing
a logic [1] to HPF. Reset clears the HPF bit. Writing a logic [0]
to HPF has no effect.
LINF—LIN Flag Bit
line. Clear LINF by writing a logic [1] to LINF. Reset clears the
LINF bit. Writing a logic [0] to LINF has no effect.
HTF—High-Temperature Flag Bit
Clear HTF by writing a logic [1] to HTF. If a high-temperature
condition is still present while writing a logic [1] to HTF, the
writing has no effect. Therefore, a high-temperature interrupt
cannot be lost due to inadvertent clearing of HTF. Reset clears
the HTF bit. Writing a logic [0] to HTF has no effect.
Reset
Read
Write
This read/write flag is set depending on RUN/STOP mode.
RUN Mode An interrupt will be generated when a state
• 1 = State change on the hallflags detected.
• 0 = No state change on the hallflags detected.
STOP Mode An interrupt will be generated when AWDCC is
• 1 = One or more of the selected Hall-effect sensor input
• 0 = None of the selected Hall-effect sensor input terminals
This read/write flag is set on the falling edge at the LIN data
• 1 = Falling edge on LIN data line has occurred.
• 0 = Falling edge on LIN data line has not occurred since
This read/write flag is set on
• 1 = High-temperature condition has occurred.
• 0 = High-temperature condition has not occurred.
MOTOROLA ANALOG INTEGRATED CIRCUIT DEVICE DATA
terminals had been pulled HIGH.
has been pulled HIGH.
last clear.
Bit7
0
0
Register Name and Address: IFR - $05
HPF
6
0
LINF
5
0
HTF
4
0
a
high-temperature condition.
LVF
3
0
HVF
2
0
OCF
1
0
Bit0
0
0

Related parts for MM908E625ACDWB/R2