AT91RM3400-AI-001 ATMEL [ATMEL Corporation], AT91RM3400-AI-001 Datasheet - Page 391

no-image

AT91RM3400-AI-001

Manufacturer Part Number
AT91RM3400-AI-001
Description
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet
AT91RM3400
• RINDE: Response Index Error
0 = No error.
1 = A mismatch is detected between the command index sent and the response index received. Cleared when writing in the
MCI_CMDR.
• RDIRE: Response Direction Error
0 = No error.
1 = The direction bit from card to host in the response has not been detected.
• RCRCE: Response CRC Error
0 = No error.
1 = A CRC7 error has been detected in the response. Cleared when writing in the MCI_CMDR.
• RENDE: Response End Bit Error
0 = No error.
1 = The end bit of the response has not been detected. Cleared when writing in the MCI_CMDR.
• RTOE: Response Time-out Error
0 = No error.
1 = The response time-out set by MAXLAT in the MCI_CMDR has been exceeded. Cleared when writing in the
MCI_CMDR.
• DCRCE: Data CRC Error
0 = No error.
1 = A CRC16 error has been detected in the last data block. Cleared when sending a new data transfer command.
• DTOE: Data Time-out Error
0 = No error.
1 = The data time-out set by DTOCYC and DTOMUL in MCI_DTOR has been exceeded. Cleared when writing in the
MCI_CMDR.
• OVRE: Overrun
0 = No error.
1 = At least one 8-bit received data has been lost (not read). Cleared when sending a new data transfer command.
• UNRE: Underrun
0 = No error.
1 = At least one 8-bit data has been sent without valid information (not written). Cleared when sending a new data transfer
command.
391
1790A–ATARM–11/03