DS1200-3-002 Emerson Network Power, DS1200-3-002 Datasheet - Page 17

no-image

DS1200-3-002

Manufacturer Part Number
DS1200-3-002
Description
POWER SUPPLY AC/DC 12V 1200W
Manufacturer
Emerson Network Power
Series
DS1200r
Datasheets

Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
EMC Immunity
DS1200-3 series power supply is designed to meet the following EMC immunity specifications:
Table 6. Environmental Specifications:
Document
FCC Docket No. 20780 Part 15
Subpart J Class B/ EN55022, Level B
EN61000-3-2
EN61000-3-3
IEC/EN 61000-4-2, Edition 1.2, 2001-04
IEC/EN 61000-4-3, 2002, Amendment 1,
2002-08
IEC/EN 61000-4-4, 1995, Amendment 2,
2001-07
IEC/EN 61000-4-5, Edition 1.1, 2001-04
IEC/EN 61000-4-11, Edition 1.1, 2001-04
EN55024:1998
Description
Conducted and Radiated EMI Limits
Harmonics
Voltage Fluctuations
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques – Electrostatic discharge immunity test. +/-15KV air, +/-8KV
contact discharge, performance Criteria B
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques, Radiated, radio-frequency, electromagnetic field immunity test
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques, Electrical Fast Transient/Burst Immunity Test. 2KV for AC
power port, 1.0KV for DC ports, I/O and signal ports performance Criteria B
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques – 2KV common mode and 1KV differential mode for AC ports
and 0.5kV differential mode for DC power, I/O and signal ports,
performance criteria B.
Electromagnetic Compatibility (EMC) - Testing and measurement
techniques : Voltage Dips and Interruptions: 30% reduction for 500ms-
Criteria B>95% reduction for 10mS, Criteria A, >95% reduction for 5000mS,
Criteria C
Information Technology Equipment-Immunity Characteristics, Limits and
Method of Measurements
Rev.10.03.30_#0.1
DS1200-3 Series
Page 17