DS1200-3-002 Emerson Network Power, DS1200-3-002 Datasheet - Page 28

no-image

DS1200-3-002

Manufacturer Part Number
DS1200-3-002
Description
POWER SUPPLY AC/DC 12V 1200W
Manufacturer
Emerson Network Power
Series
DS1200r
Datasheets

Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
Rev.10.03.30_#0.1
PS_INHIBIT – (pin B4)
DS1200-3 Series
Page 28
This signal pin should be grounded in the system. If left open, power supply operation will be inhibited
(StandBy V
output will remain on).
SB
SDA, SCL and S_INT – (pin C1, C2, D3)
Please refer to “Communication Bus Descriptions” section.
POWER GOOD– (pin C3)
The POWER GOOD is an output signal driven high, by the power supply to indicate that all outputs are valid. If any of the
power supply outputs fails below its regulation limits, this output will be driven low. The output signal is an open drain
output internally pulled up in the power supply to internal standby supply (anode side of StandBy Output or’ing circuit) via a
1K ohm resistor. It is capable of driving the output below 0.4V with a load of 4mA.
A0, A1 – (pins D1, D2)
Please refer to “Communication Bus Descriptions” section.
StandBy Remote Sense – (pin D4)
The StandBy Output of the DS1200-3 is also equipped with a Remote Sensing capability that will compensate upto 50mV
of voltage drop for the positive rail. The StandBy Output Remote Sense pin should be connected as close to the load as
possible, or connected to the StandBy Output pins at the base of the output connector if not used. If left open, the remote
sense might not work properly and the voltage level of StandBy Output can be lower than the guaranteed spec.

Related parts for DS1200-3-002