DS1200-3-002 Emerson Network Power, DS1200-3-002 Datasheet - Page 49

no-image

DS1200-3-002

Manufacturer Part Number
DS1200-3-002
Description
POWER SUPPLY AC/DC 12V 1200W
Manufacturer
Emerson Network Power
Series
DS1200r
Datasheets

Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
DS1200-3 Series Support PMBus
The DS1200-3 is compliant with the industry standard PMBus
power supply via the i
DS1200-3 Series Supported PMBus
Command
Code
01h
02h
03h
10h
11h
12h
15h
16h
Command Name
OPERATION
b7:6
b5:4
b3:2
b1:0
ON_OFF_CONFIG
b7:5
b4 – Enable PS_ON pin and
Serial communication control.
b3 – Serial communication
Control
b2 – Sets how the unit responds
to PS_ON pin
b1 – PS_ON pin polarity
b0 – PS_ONL pin action
CLEAR_FAULTS
WRITE_PROTECT
STORE_DEFAULT_ALL
RESTORE_DEFAULT_ALL
STORE_USER_ALL
RESTORE_USER_ALL
2
C interface port.
TM
Command List:
TM
Default Value
Command List
10b
00b
00b
00b
000
1C
80
00
1
1
1
0
0
0
-
-
-
-
Access
Type
R/W
R/W
R
S
S
S
S
S
TM
protocol for monitoring and control of the
Bytes
Data
1
1
1
0
0
0
0
Format
Data
Used to turn the unit ON/OFF in conjunction
with the input PS_ON pin.
00 – Immediate Turn OFF (No Sequencing )
01 – Soft Turn OFF (With Sequencing)
10 – PSU ON
Reserved
Configures the combination of PS_ON pin and
serial communication commands needed to turn
the unit ON/OFF.
Reserved
0 – Unit powers up any time power is present
regardless of the state of PS_ON pin.
1 – Unit powers up as dictated by PS_ON pin
and OPERATION command (b3:0) .
0 – Unit Ignores ON/OFF portion of the
OPERATION command.
1 – Enables Serial communication ON/OFF
portion of OPERATION command.
Requires PS_ON pin to be asserted for the unit
to start and energize the output.
0 – Unit ignores PS_ON pin. (ON/OFF
controlled by OPERATION command).
1 – Unit requires PS_ON pin to be asserted to
start the unit.
0 – Active Low (Pull Low to start the unit).
1 – Active high (Pull high to start the unit).
0 – Use programmed turn ON/OFF delay.
1 – Turn OFF the output and stop transferring
energy to the output as fast as possible.
Used to Control Writing to the PMBus Device
80h - Disables write except 10h
40h – Disables write except 10h, 01h, 00h
20h – Disables write except 10h,01h,00h,02h
and 21h commands
00 – Enables write to all writeable commands.
Copies the Value of the Operating memory table
to the matching DEFAULT non-volatile memory.
Copies the entire contents of the DEFAULT
non-volatile memory to the Operating memory
table.
Copies the Operating memory table to the
matching USER non-volatile memory.
Copies the entire USER non-volatile memory to
the Operating memory table.
Description
Rev.10.03.30_#0.1
DS1200-3 Series
Page 49

Related parts for DS1200-3-002