DS1200-3-002 Emerson Network Power, DS1200-3-002 Datasheet - Page 57

no-image

DS1200-3-002

Manufacturer Part Number
DS1200-3-002
Description
POWER SUPPLY AC/DC 12V 1200W
Manufacturer
Emerson Network Power
Series
DS1200r
Datasheets

Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
Rev.10.03.30_#0.1
Redundancy / Fault Tolerance
DS1200-3 Series
Page 57
The DS1200-3 series power supplies will allow up to 4 power supplies to be connected in an N+1 redundant
load.
Any failure of one power supply in parallel as well as hot swapping shall not cause more than a 5% change in any output.
Current share accuracy is typically 5% of full load. The Failure of one or more supplies will not cause the remaining
supplies to violate any of the input or output specifications noted in this specification including all status signals.
The latch of the DS1200-3 power supply is designed to prevent the latch from depressed if the AC cord is attached to the
power supply. In order to remove the power supply from system chassis, the AC cord must be removed first so the power
supply will always be in the powered off state during the removal from system chassis.