Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
DS1200-3 Series Supported PMBus
Command
Code
7Ah
7Bh
7Ch
7Dh
7Eh
Command Name
STATUS_VOUT
b7
b6
b5
b4
b3
b2
b1
b0
STATUS_IOUT
b7
b6
b5
b4
b3
b2
b1
b0
STATUS_INPUT
b7
b6
b5
b4
b3
b2
b1
b0
STATUS_TEMPERATURE
b7
b6
b5
b4
b3:0
STATUS_CML
b7
b6
b5
b4
b3
b2
b1
b0
TM
Command List:
Default Value
-
-
-
-
Access
Type
R
R
R
R
R
Bytes
Data
1
1
1
1
1
Format
Data
Output voltage related faults and warnings
VOUT Over--voltage Fault
VOUT Over-voltage warning
VOUT Under-voltage Warning
VOUT Under-voltage Fault
VOUT_MAX Warning, an attempt has been
made to set output to a value higher that the
highest permissible voltage.
TON_MAX_FAULT
TOFF_MAX Warning
reserved
Output Current related faults and warnings
IOUT Over current Fault
IOUT Over current And Low Voltage shutdown
Fault
VOUT Under-voltage Warning
VOUT Under-voltage Fault
VOUT_MAX Warning, an attempt has been
made to set output to a value higher that the
highest permissible voltage.
TON_MAX_FAULT
TOFF_MAX Warning
reserved
Input related faults and warnings
VIN Overvoltage Fault
VIN Overvoltge Warning
VIN Undervoltage Warning
VIN Undervoltage Fault
Unit is OFF for insufficient Input Voltage
IIN Overcurrent Fault
IIN Overcurrent Warning
PIN overpower Warning
Temperature related faults and warnings
Overtemperature Fault
Overtemperature Warning
Undertemperature Warning
Undertemperature Fault
reserved
Communications, Logic and Memory
Invalid or unsupported Command Received
Packet Error Check Failed
Memory Fault Detect, CRC Error
Description
Rev.10.03.30_#0.1
DS1200-3 Series
Page 53