Specifications of DS1200-3-002

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
1200W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
180 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
12 VDC @ 100A
Size / Dimension
11" L x 3.2" W x 1.57" H (279.4mm x 81.3mm x 39.9mm)
Power (watts) - Rated
1200W
Operating Temperature
-10°C ~ 50°C
Efficiency
91%
Approvals
CB, CE, cUL, EN, NEMKO, UL
Line Regulation
±5%
Load Regulation
±5%
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
454-1271
EMI Emissions
The DS1200 series has been designed to comply with the Class B limits of EMI requirements of EN55022
(FCC Part 15) and CISPR 22 (EN55022) for emissions and relevant sections of EN61000 (IEC 61000) for immunity.
The unit is enclosed inside a metal box, tested at 1200W using resistive load with cooling fan.
Conducted Emissions
The applicable standard for conducted emissions is EN55022 (FCC Part 15). Conducted noise can appear as both
differential mode and common mode noise currents. Differential mode noise is measured between the two input lines, with
the major components occurring at the supply fundamental switching frequency and its harmonics. Common mode noise,
a contributor to both radiated emissions and input conducted emissions, is measured between the input lines and system
ground and can be broadband in nature.
Conducted Emissions
Table 6. Conducted EMI emission specifications of the DS1200-3 series
Parameter
FCC Part 15, class B
VCCI Class II
EN 60601-1-2: 2001
CISPR 22 (EN55022) class B
Model
All
All
All
All
Symbol
Margin
Margin
Margin
Margin
The DS1200-3 power supplies have internal EMI filters to
ensure the convertors’ conducted EMI levels comply with
EN55022 (FCC Part 15) Class B and EN55022 (CISPR
22) Class B limits. The EMI measurements are
performed with resistive loads at maximum rated loading.
Sample of EN55022 Conducted EMI Measurement at
100Vac input
Note:
Red Line refers to Emerson Quasi Peak margin,
which is 6dB below the CISPR international limit.
Pink Line refers to the Emerson Average margin,
which is 6dB below the CISPR international limit.
Min
-
-
-
-
Typ
-
-
-
-
Max
6
6
6
6
Rev.10.03.30_#0.1