STEVAL-IPE009V1 STMicroelectronics, STEVAL-IPE009V1 Datasheet - Page 18

BOARD EVAL ST72321BR9/STPM14

STEVAL-IPE009V1

Manufacturer Part Number
STEVAL-IPE009V1
Description
BOARD EVAL ST72321BR9/STPM14
Manufacturer
STMicroelectronics
Type
Other Power Managementr
Datasheets

Specifications of STEVAL-IPE009V1

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
STPM14, ST72F321BR9T6
Primary Attributes
1-Ph 220 VAC, LCD Displays: No-Load, Reverse, Fraud, or Case Tampering
Secondary Attributes
Up to 4 Tariff Rates, Data Accumulated for Meter Life, Time Stamp for: Tamper, Fraud, Power Failure
Input Voltage
220 V
Product
Power Management Modules
Silicon Manufacturer
ST Micro
Silicon Core Number
ST72321BR9 And STPM14
Features
Continuously Detects, Displays No-Load Condition, Reverse Direction, Fraud And Case Tamper Condition
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
STPM14, ST72321BR9
Other names
497-8434
STEVAL-IPE009V1
Theory of operation
Table 10.
7.5
18/46
Rogowsky
CT-Shunt
Equation 1
(CT/Shunt)
Equation 2
(Rogowsky)
Where K
The BFR flag is cleared when the V
error is set, the computation of power is suspended and MOP, MON and LED will be held
low.
RMS voltage check
Single wire meter mode (STPM13/14 with Rogowsky coil
sensor)
STPM1X supports the single wire meter (SWM) operation when working with Rogowsky
Coil current sensors. In SWM mode there is no available voltage information in the voltage
channel. It is possible that someone has disconnected one wire (live or neutral) of the meter
for tampering purposes or in case the line voltage is very stable, it is possible to use a
predefined value for computing the energy without sensing it.
In order to enable the SWM mode, the STPM1X must be configured with PST values of 0 or
1. In this way, if the BFR error is detected, STPM1X enters in SWM. If BFR is cleared, the
energy calculation is performed normally. When BFR is set (no voltage information is
available), the energy computation is carried out using a nominal voltage value according to
the NOM configuration bits.
Since there is no information on the phase shift between voltage and current, the apparent
rather than active power is used for tamper and energy computation. The calculated
apparent energy will be the product between I
V
V
STPM1X and K
V
V
RMS
RMS
IRMS
IRMS
=VPK*K
that can be calculated as follows:
BFR
BFR
V
is the voltage calibrator value ranging from 0.875 to 1.000.
=
=
6703
6687
NOM
NOM
64
64
, where VPK represents the maximum line voltage reading of the
K
K
is a coefficient that changes according to
V
V
0.009571/Kv
0.0078/Kv
BFR-on
Doc ID 13167 Rev 7
IRMS
value goes above twice V
RMS
(effectively measured) and an equivalent
STPM11, STPM12, STPM13, STPM14
Table
0.019142/Kv
0.0156/Kv
IRMS-BFR
BFR-off
11:
. When the BFR

Related parts for STEVAL-IPE009V1