C8051F800DK Silicon Laboratories Inc, C8051F800DK Datasheet - Page 215

KIT DEV C8051F800

C8051F800DK

Manufacturer Part Number
C8051F800DK
Description
KIT DEV C8051F800
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F800DK

Contents
Board, Cables, CD, Debugger, Power Supply
Processor To Be Evaluated
C8051F800
Data Bus Width
16 bit
Interface Type
USB
Operating Supply Voltage
7 V to 15 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F8xx
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
336-1797
SFR Definition 28.2. TCON: Timer Control
SFR Address = 0x88; Bit-Addressable
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
Name
TR1
TR0
TF1
TF0
IE1
IE0
IT1
IT0
R/W
TF1
7
0
Timer 1 Overflow Flag.
Set to 1 by hardware when Timer 1 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 1 interrupt service
routine.
Timer 1 Run Control.
Timer 1 is enabled by setting this bit to 1.
Timer 0 Overflow Flag.
Set to 1 by hardware when Timer 0 overflows. This flag can be cleared by software
but is automatically cleared when the CPU vectors to the Timer 0 interrupt service
routine.
Timer 0 Run Control.
Timer 0 is enabled by setting this bit to 1.
External Interrupt 1.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 1 service routine in edge-triggered mode.
Interrupt 1 Type Select.
This bit selects whether the configured /INT1 interrupt will be edge or level sensitive.
/INT1 is configured active low or high by the IN1PL bit in the IT01CF register (see
SFR Definition 18.7).
0: /INT1 is level triggered.
1: /INT1 is edge triggered.
External Interrupt 0.
This flag is set by hardware when an edge/level of type defined by IT1 is detected. It
can be cleared by software but is automatically cleared when the CPU vectors to the
External Interrupt 0 service routine in edge-triggered mode.
Interrupt 0 Type Select.
This bit selects whether the configured INT0 interrupt will be edge or level sensitive.
INT0 is configured active low or high by the IN0PL bit in register IT01CF (see SFR
Definition 18.7).
0: INT0 is level triggered.
1: INT0 is edge triggered.
TR1
R/W
6
0
R/W
TF0
5
0
TR0
R/W
Rev. 1.0
4
0
Function
R/W
IE1
3
0
C8051F80x-83x
R/W
IT1
2
0
R/W
IE0
1
0
R/W
IT0
0
0
215