KIT DEVELOPMENT FOR C8051T606

C8051T606DK

Manufacturer Part Number
C8051T606DK
Description
KIT DEVELOPMENT FOR C8051T606
Manufacturer
Silicon Laboratories Inc
Type
MCUr

Specifications of C8051T606DK

Contents
Board, Adapter, Cable, CD, Power Supply
Processor To Be Evaluated
C8051T606x
Interface Type
RS-232, USB
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
3.3 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051T606
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1666
C8051T600/1/2/3/4/5/6
26. Programmable Counter Array
The Programmable Counter Array (PCA0) provides enhanced timer functionality while requiring less CPU
intervention than the standard 8051 counter/timers. The PCA consists of a dedicated 16-bit counter/timer
and three 16-bit Capture/Compare modules. Each Capture/Compare module has its own associated I/O
line (CEXn) which is routed through the Crossbar to Port I/O when enabled. The counter/timer is driven by
a programmable timebase that can select between six sources: system clock, system clock divided by four,
system clock divided by twelve, the external oscillator clock source divided by eight, Timer 0 overflows, or
an external clock signal on the ECI input pin. Each Capture/Compare module may be configured to oper-
ate independently in one of six modes: Edge-Triggered Capture, Software Timer, High-Speed Output, Fre-
quency Output, 8-Bit PWM, or 16-Bit PWM (each mode is described in Section “26.3. Capture/Compare
Modules” on page 163). The external oscillator clock option is ideal for real-time clock (RTC) functionality,
allowing the PCA to be clocked by a precision external oscillator while the internal oscillator drives the sys-
tem clock. The PCA is configured and controlled through the system controller's Special Function Regis-
ters. The PCA block diagram is shown in Figure 26.1
Important Note: The PCA Module 2 may be used as a Watchdog Timer (WDT), and is enabled in this
mode following a system reset. Access to certain PCA registers is restricted while WDT mode is
enabled. See Section 26.4 for details.
160
Figure 26.1. PCA Block Diagram
Capture/Compare
Module 0
SYSCLK/12
Timer 0 Overflow
SYSCLK
External Clock/8
SYSCLK/4
ECI
Crossbar
Port I/O
Rev. 1.2
Capture/Compare
Module 1
CLOCK
MUX
PCA
16-Bit Counter/Timer
Capture/Compare
Module 2 / WDT