STV-974/552S-R01 STMicroelectronics, STV-974/552S-R01 Datasheet - Page 46

no-image

STV-974/552S-R01

Manufacturer Part Number
STV-974/552S-R01
Description
KIT DEMO W/VS6552
Manufacturer
STMicroelectronics

Specifications of STV-974/552S-R01

Sensor Type
CMOS Imaging, Color (RGB)
Sensing Range
VGA
Interface
I²C
Sensitivity
30 fps
Embedded
No
Utilized Ic / Part
STV0974E, VS6552
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-3891
STV0974
Note:
Register group 3
Table 30: Color management [register group 3]
YCbCr control registers are common for still/live and ViewFinder modes. As a consequence, if
different settings are applied in these modes and if for example still capture is requested from
ViewFinder mode, it is recommended to set a “transfer mode delay” corresponding to 1 frame
minimum, and also to respect a minimum wait of half of a frame prior to changing the YCbCr
settings.
Still / live Gamma
Standard Gain
Still / live Gamma
S-Curve gain
Still / live Gamma
Misc.
Viewfinder
Gamma
Standard Gain
Viewfinder
Gamma
S-Curve gain
Viewfinder
Gamma Misc.
YCbCr Control
Y range
YCbCr Control
Y ceiling
YCbCr Control
Y floor
YCbCr Control
CbCr saturation
a. The maximum register value allowed is 144. For higher saturation capabilities, contact ST support.
Name
a
0xA300
0xA301
0xA302
0xA303
0xA304
0xA305
0xA306
0xA307
0xA308
0xA309
Index
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
State
code
A
A
A
A
A
A
A
A
A
A
Data
type
M
M
M
M
M
M
M
I
I
I
RRRR.DDDD
0000.0011
XXXX.DDDD
DDDD.XXXX
0100.0100
XRRR.DDDD
DRRR.XXXX
1000.0000
RRRR.DDDD
0000.0100
XXXX.DDDD
DDDD.XXXX
0100.0100
XRRR.DDDD
DRRR.XXXX
1000.0000
DDDD.DDDD
DDDD.DDDD
DDDD.XXXX
DDDD.XXXX
1000.0000
0001.0000
0000.0000
1000.0000
Format
default
Bit[3:0]: gain for standard Gamma
curve
Bit[3:0]: Gain for low S-curve part
Bit[7:4]: Gain for high S-curve part
Bit[3:0]: S-curve pedestal
bit [7] = 1 Standard Gamma
bit[7] = 0 S-curve Gamma
Bit[3-0]: Gain for standard Gamma
curve
Bit[3-0]: Gain for low S-Curve part
Bit[7-4]: Gain for high S-Curve part
Bit[3:0]: S-curve pedestal
bit [7] = 1 Standard Gamma
bit [7] = 0 S-curve Gamma
Y range value
(contrast enhancement)
Bit[7:4]: Ceiling value
Bit[3:0]: Floor value (signed value
in 2’s complement)
CbCr saturation
Functional description
Description
46/61