ATTINY461V-10SU Atmel, ATTINY461V-10SU Datasheet - Page 28

IC MCU AVR 4K FLASH 10MHZ 20SOIC

ATTINY461V-10SU

Manufacturer Part Number
ATTINY461V-10SU
Description
IC MCU AVR 4K FLASH 10MHZ 20SOIC
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheets

Specifications of ATTINY461V-10SU

Core Processor
AVR
Core Size
8-Bit
Speed
10MHz
Connectivity
USI
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
16
Program Memory Size
4KB (2K x 16)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 11x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-SOIC (7.5mm Width)
Processor Series
ATTINY4x
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
2-Wire, SPI, USI
Maximum Clock Frequency
10 MHz
Number Of Programmable I/os
16
Number Of Timers
2
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit
Package
20SOIC W
Device Core
AVR
Family Name
ATtiny
Maximum Speed
10 MHz
For Use With
ATSTK600 - DEV KIT FOR AVR/AVR32ATAVRBC100 - REF DESIGN KIT BATTERY CHARGER770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAG770-1004 - ISP 4PORT FOR ATMEL AVR MCU SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATTINY461V-10SU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATTINY461V-10SUR
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
6.2.3
28
ATtiny261/461/861
Calibrated Internal 8 MHz Oscillator
When the PLL output is selected as clock source, the start-up times are determined by SUT fuse
bits as shown in
Table 6-5.
By default, the Internal Oscillator provides an approximately 8 MHz clock signal. Though voltage
and temperature dependent, this clock can be very accurately calibrated by the user. See
19-2 on page 189
shipped with the CKDIV8 Fuse programmed. See
more details.
This clock may be selected as the system clock by programming the CKSEL Fuses as shown in
Table
the pre-programmed calibration value into the OSCCAL Register and thereby automatically cal-
ibrates the RC Oscillator. The accuracy of this calibration is shown as Factory calibration in
Table 19-2 on page
Table 6-6.
Notes:
When this oscillator is selected, start-up times are determined by SUT fuses as shown in
6-7.
Table 6-7.
Note:
SUT1:0
SUT1:0
10
00
01
10
11
00
01
11
(2)
6-6. If selected, it will operate with no external components. During reset, hardware loads
1. The device is shipped with this option selected.
2. If the oscillator frequency exceeds the specification of the device (depends on V
1. If the RSTDISBL fuse is programmed, this start-up time will be increased to 14CK + 4 ms to
2. The device is shipped with this option selected.
CKDIV8 Fuse can be programmed to divide the internal frequency by 8.
ensure programming mode can be entered.
14CK + 16K (16384) + 64 ms
14CK + 16K (16384) + 4 ms
CKSEL3:0
14CK + 1K (1024) + 64 ms
14CK + 1K (1024) + 4 ms
Start-up Times for the PLLCK
Internal Calibrated RC Oscillator Operating Modes
Start-up Times for the Internal Calibrated RC Oscillator Clock Selection
0010
Table
Start-up Time from
from Power-down
and
Power Down
(1)
189.
Start-up Time
6-5.
“Internal Oscillator Speed” on page 216
6 CK
6 CK
6 CK
Power-On-Reset (V
Additional Delay from
Additional Delay from
Reset (V
Reserved
14CK + 64 ms
14CK + 4 ms
“System Clock Prescaler” on page 31
14CK
4 ms
4 ms
4 ms
4 ms
CC
Nominal Frequency
(1)
= 5.0V)
CC
8.0 MHz
= 5.0V)
for more details. The device is
(2)
Recommended
Usage
BOD enabled
Fast rising power
Slowly rising power
Recommended
usage
BOD enabled
Fast rising power
Slowly rising power
Slowly rising power
2588E–AVR–08/10
CC
), the
Table
Table
for