AT32UC3A0512-ALTTA Atmel, AT32UC3A0512-ALTTA Datasheet - Page 575

IC MCU AVR32 512K FLASH 144LQFP

AT32UC3A0512-ALTTA

Manufacturer Part Number
AT32UC3A0512-ALTTA
Description
IC MCU AVR32 512K FLASH 144LQFP
Manufacturer
Atmel
Series
AVR®32 UC3r
Datasheet

Specifications of AT32UC3A0512-ALTTA

Core Processor
AVR
Core Size
32-Bit
Speed
66MHz
Connectivity
EBI/EMI, Ethernet, I²C, SPI, SSC, UART/USART, USB OTG
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
109
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3A0512-ALTTA
Manufacturer:
Atmel
Quantity:
10 000
Shall be cleared by software (by setting the OVERFIC bit) to acknowledge the interrupt.
• STALLEDI: STALLed Interrupt Flag
Set by hardware to signal that a STALL handshake has been sent. To do that, the software has to set the STALLRQ bit (by
setting the STALLRQS bit). This triggers an EPXINT interrupt if STALLEDE = 1.
Shall be cleared by software (by setting the STALLEDIC bit) to acknowledge the interrupt.
• CRCERRI: CRC Error Interrupt Flag
Set by hardware to signal that a CRC error has been detected in an isochronous OUT endpoint. The OUT packet is stored
in the bank as if no CRC error had occurred. This triggers an EPXINT interrupt if CRCERRE = 1.
Shall be cleared by software (by setting the CRCERRIC bit) to acknowledge the interrupt.
• SHORTPACKET: Short Packet Interrupt Flag
For non-control OUT endpoints, set by hardware when a short packet has been received.
For non-control IN endpoints, set by hardware when a short packet is transmitted upon ending a DMA transfer, thus signal-
ing an end of isochronous frame or a bulk or interrupt end of transfer, this only if the End of DMA Buffer Output Enable bit
(DMAEND_EN) and the Automatic Switch bit (AUTOSW) are set.
This triggers an EPXINT interrupt if SHORTPACKETE = 1.
Shall be cleared by software (by setting the SHORTPACKETC bit) to acknowledge the interrupt.
• DTSEQ: Data Toggle Sequence
Set by hardware to indicate the PID of the current bank:
For IN transfers, it indicates the data toggle sequence that will be used for the next packet to be sent. This is not relative to
the current bank.
For OUT transfers, this value indicates the last data toggle sequence received on the current bank.
Note that by default DTSEQ = 01b, as if the last data toggle sequence was Data1, so the next sent or expected data toggle
sequence should be Data0.
• NBUSYBK: Number of Busy Banks
Set by hardware to indicate the number of busy banks:
For IN endpoints, it indicates the number of banks filled by the user and ready for IN transfer. When all banks are free, this
triggers an EPXINT interrupt if NBUSYBKE = 1.
32058J–AVR32–04/11
0
0
1
0
0
1
1
NBUSYBK
DTSEQ
X
0
1
0
1
0
1
Data Toggle Sequence
Data0
Data1
Reserved
Number of Busy Banks
0 (all banks free)
1
2
3
AT32UC3A
575

Related parts for AT32UC3A0512-ALTTA