CLRC63201T/0FE,112 NXP Semiconductors, CLRC63201T/0FE,112 Datasheet - Page 76

IC I.CODE HS READER 32-SOIC

CLRC63201T/0FE,112

Manufacturer Part Number
CLRC63201T/0FE,112
Description
IC I.CODE HS READER 32-SOIC
Manufacturer
NXP Semiconductors
Series
I-Coder
Datasheets

Specifications of CLRC63201T/0FE,112

Rf Type
Read Only
Frequency
13.56MHz
Features
ISO14443-A, ISO14443-B, ISO15693, ISO18000-3
Package / Case
32-SOIC (0.300", 7.50mm Width)
Product
RFID Readers
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-2199-5
935269690112
CLRC632
CLRC63201TD

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CLRC63201T/0FE,112
Manufacturer:
IR
Quantity:
3 400
Part Number:
CLRC63201T/0FE,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
11. CLRC632 command set
Table 133. CLRC632 commands overview
CLRC632_35
Product data sheet
PUBLIC
Command
StartUp
Idle
Transmit
Receive
10.5.8.7 Reserved registers 3Eh, 3Fh
Value Action
3Fh
00h
1Ah
16h
11.1 CLRC632 command overview
runs the reset and initialization phase. See
transmits data from the FIFO buffer to the card. See
Section 11.1.2 on page
Remark: This command can only be activated by
Power-On or Hard resets.
no action; cancels execution of the current command.
See
Section 11.2.1 on page 79
activates receiver circuitry. Before the receiver starts,
the state machine waits until the time defined in the
RxWait register has elapsed. See
page
Remark: This command may be used for test
purposes only, since there is no timing relationship to
the Transmit command.
Table 132. Reserved register (address: 3Eh, 3Fh) reset value: xxxx xxxxb, xxh bit allocation
Remark: This register is reserved for future use.
CLRC632 operation is determined by an internal state machine capable of performing a
command set. The commands can be started by writing the command code to the
Command register. Arguments and/or data necessary to process a command are mainly
exchanged using the FIFO buffer.
Bit
Symbol
Access
Section 11.1.3 on page 78
82.
Each command needing a data stream (or data byte stream) as an input immediately
processes the data in the FIFO buffer
Each command that requires arguments only starts processing when it has received
the correct number of arguments from the FIFO buffer
The FIFO buffer is not automatically cleared at the start of a command. It is, therefore,
possible to write command arguments and/or the data bytes into the FIFO buffer
before starting a command.
Each command (except the StartUp command) can be interrupted by the
microprocessor writing a new command code to the Command register e.g. the Idle
command.
W
7
x
78.
Rev. 3.5 — 10 November 2009
W
6
x
Multiple protocol contactless reader IC (MIFARE/I-CODE1)
Section 11.2.2 on
073935
W
5
x
W
4
x
FIFO communication
Arguments and data
sent
-
-
data stream
-
W
3
x
W
2
x
CLRC632
© NXP B.V. 2009. All rights reserved.
Data received
-
-
-
data stream
W
1
x
76 of 126