IS-C1603 NKK Switches, IS-C1603 Datasheet - Page 24

CONTROL FOR 36X24 LCD PB/DISPLAY

IS-C1603

Manufacturer Part Number
IS-C1603
Description
CONTROL FOR 36X24 LCD PB/DISPLAY
Manufacturer
NKK Switches
Datasheet

Specifications of IS-C1603

Accessory Type
Controller
Description/function
SMARTSWITCH Development Kit
For Use With/related Products
SmartSwitch™ Switches
For Use With
IS01BCEF - SMARTDISPLAY SUPER YEL/GRN LEDIS01BCE - SMARTDISPLAY SUPER YELLOW LEDIS15SBFP4B - SMARTSWITCH COMPACT WHITE LEDIS15SBCP4EF - SMARTSWITCH COMPACT YEL/GRN LEDIS15SACP4CF - SMARTSWITCH COMPACT RED/GRN LEDIS15ABFP4B - SMARTSWITCH STD BLK W/WHITE LEDIS15ABDP4B - SMARTSWITCH STD BLU W/WHITE LEDIS15ABDP4EG - SMARTSWITCH STD YELLOW/BLUE LEDIS15ABDP4E - SMARTSWITCH STD BLUE W/YEL LEDIS15ABCP4EF - SMARTSWITCH STD YEL/GRN LEDIS15ABCP4E - SMARTSWITCH STD LED YELLOWIS15AACP4CF - SMARTSWITCH STD YEL RED/GRN LED360-2334 - SMARTDISPLAY RED/GREEN/BLUE360-2333 - SMARTDISPLAY SUPER RED/GREEN LED360-2332 - SMARTSWITCH STANDARD RED/GRN/BLU360-2331 - SMARTSWITCH COMPACT RED/GRN/BLU360-2330 - SMARTSWITCH STD RED/GRN LED360-2329 - SMARTSWITCH COMPACT RED/GRN LED
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
360-2427
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
Flag Byte C bit settings:
B0=0 ---> No transmission.
B0=1 ---> Upon switch release, transmit Pointer value of the switch in ASCII HEX format.
B1=0 ---> No transmission.
B1=1 ---> Upon switch release, transmit from the user-defined Image release event data. Up to 16
B2=0 ---> No transmission.
B2=1 ---> Upon switch release, transmit from the user-defined switch release event data. Up to 16
B3=0 ---> Disable user-defined Image press repeat.
B3=1 ---> Enable user-defined Image press repeat. Repeatedly transmits user-defined Image release
B4
B5
B6=0 ---> Disable timer for command 26H.
B6=1 ---> Enable timer for command 26H. Controller waits for additional optional bytes until user-
B7=0 ---> Normal operation mode.
B7=1 ---> Continuous command operation mode. Turns the user-defined timer on for two
This command is for set-up/testing of the controller. The controller is put into the set-up mode, where any
number of options may be transmitted. This is the only command where the timer between two consecutive
received bytes is not set. The user must exit this mode by sending X (58H) or ESC (1BH). It is recommended
that the B6 of Flag-C to be set during the operation.
Command 26H.
IS-C1603 Intelligent Controller Users Manual C.doc
9. Controller Set-up, Command 26H
B7
---> Reserved. Must be set to zero. RS422 only.
---> Reserved. Must be set to zero. RS422 only.
command format:
transmit format:
bytes or until a byte value is 00H.
bytes or until a byte value is 00H.
event data upon Image press event in XXH format.
defined timer expires. (50ms)
consecutive commands. If the timer expires before the controller receives the next
command, blinking red codes are put into the refresh Buffer for all the switches.
This is for applications in which the host continuously communicates with the
controller. Blinking red indicate to the operator that controller is off line.
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
1
Continuous command operation
mode
(xxH)
26H
IS-C1603 Intelligent Controller Users
www.nkkswitches.com • Email engineering@nkkswitches.com
[Option(s)]
(xxH)
Manual
Turn all the Module backlighting
blinking red if no command from host is
received within user-define time interval.
Page 24 of 45