PEB22504HT-V11 Infineon Technologies, PEB22504HT-V11 Datasheet - Page 71

no-image

PEB22504HT-V11

Manufacturer Part Number
PEB22504HT-V11
Description
IC INTERFACE QUAD 100-TQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB22504HT-V11

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
100-LFQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB22504HT-V11
PEB22504HT-V11IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB22504HT-V11
Manufacturer:
Infineon Technologies
Quantity:
10 000
LOSR(1:0)
Data Sheet
Loss-of-Signal Recovery Condition
00 = The LOS alarm is cleared if the predefined pulse-density
01 = In addition to the recovery condition described above a LOS
10 = A LOS alarm is not terminated, if at the end of the pulse position
11 = In addition to the recovery condition described for "00" a LOS
(register PCR) is detected during the time interval which is
defined by register PCD.
alarm is cleared only if the pulse-density requirement (defined
by PCR and PCD) is fulfilled and no more than 15 contiguous
zeros are detected during the recovery interval.
interval any subinterval of 100 pulse positions contains no
pulses of either polarity (ANSI T1.231). This means, clearing a
LOS alarm is done only if the pulse-density requirement
(defined by PCR and PCD) is fulfilled and no more than 99
contiguous zeros are detected during the recovery interval.
alarm is cleared only if the pulse-density requirement (defined
by PCR and PCD) is fulfilled and no more than 8 contiguous
zeros are detected during the recovery interval.
71
Register Description
QuadLIU V1.1
PEB 22504
2001-02

Related parts for PEB22504HT-V11