AT90PWM161 Atmel Corporation, AT90PWM161 Datasheet - Page 311

no-image

AT90PWM161

Manufacturer Part Number
AT90PWM161
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT90PWM161

Flash (kbytes)
16 Kbytes
Pin Count
20
Max. Operating Frequency
16 MHz
Cpu
8-bit AVR
Hardware Qtouch Acquisition
No
Max I/o Pins
20
Ext Interrupts
3
Usb Speed
No
Usb Interface
No
Spi
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
11
Adc Resolution (bits)
10
Adc Speed (ksps)
125
Analog Comparators
3
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.25
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 125
I/o Supply Class
2.7 to 5.5
Operating Voltage (vcc)
2.7 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
1
Output Compare Channels
8
Input Capture Channels
1
Pwm Channels
6
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90PWM161-16MN
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT90PWM161-WN
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
7734P–AVR–08/10
1. Clock Switch enable & disable
2. Crystal oscillator control with Clock Switch
3. BOD disable fuse
4. PSC output at Reset
5. Flash and EEPROM programming failure if CPU clock is switched
6. ADC AMPlifier measurement is unstable
After a “Enable Clock Source” or a “Disable Clock Source” command, the command is still
active until the next access of CLKCSR register. If CLKSEL is written with a new value, the
corresponding clock will be unintentionnaly enabled or disabled.
Work around:
Atter the Enable or Disable command, write CLKCSR with value 1<<CLKCCE
When a Xtal oscillator is active and CLKSELR is written with a new value for the selection of
another clock source (for instance RC or WD) , the Xtal oscillator gain is not correct.
Work around:
After the commands “Enable Clock Source” and “Clock Source Switching”, write back CLK-
SELR with the values corresponding to the active Xtal oscillator
It is strongly advised to keep the BOD active. Indeed, the RC oscillator may lock if it is acti-
vated when the power suppy goes at a low voltage.
Work around:
If it is mandatory to disable the BOD, do not set the RC oscillator as clock source during
reset and makes sure the RC oscillator is never active when the power supply is below the
lowest POR voltage (2.6V).
At Reset, the PSC outputs may be set at a value different from the PSC Fuse configuration
(Bit 4 of Extended Fuse Byte).
Work around:
Initiate PSC output states from source code.
If Clock switching is used in the Application, the memory programming is only possible when
the internal RC oscillator is selected as System clock.
If the Application requires a memory programming on a clock source different from the inter-
nal RC oscillator, do not switch to this clock source.
Work around:
- Use internal RC oscillator when programming Flash and EEPROM,
or
- Do not use clock switching
When switching from a single-ended ADC channel to an Amplified channel, noise can
appear on ADC conversion.
Work around:
After switching from a single ended to an amplified channel, discard the first ADC
conversion.
AT90PWM81
311

Related parts for AT90PWM161