TMPM364F10FG Toshiba, TMPM364F10FG Datasheet - Page 717

no-image

TMPM364F10FG

Manufacturer Part Number
TMPM364F10FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM364F10FG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
1024K
Rom Type
Flash
Ram (kbytes)
64K
Number Of Pins
144
Package
LQFP(20x20)
Vcc
3V
Cpu Mhz
64
Ssp (ch) Spi
1
I2c/sio (ch)
5
Uart/sio (ch)
12
Usb
Host
Can
1
Ethernet
-
External Bus Interface
Y
Cs/wait Controller (ch)
4
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
16
12-bit Ad Converter
-
16-bit Timer / Counter
16
Motor / Igbt Control
-
Real Time Clock
Y
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
Y
Remote Control Interface
Y
Hardware Cec Controller
Y
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM364F10FG
Manufacturer:
Toshiba
Quantity:
10 000
Company:
Part Number:
TMPM364F10FG
Quantity:
6 000
22.4.3
22.4.2.2
bled. If the value of the conversion result register specified by ADMOD3<ADREGS0> and AD-
MOD5<ADREGS1> becomes larger or smaller ("Larger" or "Smaller" to be designated by ADMOD3<ADO-
BIC0> and ADMOD5<ADBIC1>) than the value of a comparison register, the AD monitor function inter-
rupt (INTADM0,INTADM1) is generated. This comparison operation is performed each time a result is stor-
ed in a corresponding conversion result register.
reading the conversion result, the conversion result is overwritten. The conversion result storage flag
<ADRxRF> and the overrun flag <OVRx> remain being set.
There are two channels of AD monitor function.
If ADMOD3<ADOBSV0> and ADMOD5<ADOBSV1> are set to "1", the AD monitor function is ena-
If the conversion result register assigned to perform the AD monitor function is continuously used without
PEAT,SCAN> setting. When conditions to start operation are met, a conversion is performed just once
for a channel designated by ADMOD2<HPADCH>. When conversion is completed, the top-priority AD
conversion completion interrupt (INTADHP) is generated, and ADMOD2<EOCFHP> showing the comple-
tion of AD conversion is set to "1". <ADBFHP> returns to "0". EOCFHP flag is cleared to "0" upon read.
AD Monitor Function
(3)
(4)
By interrupting ongoing normal AD conversion, top-priority AD conversion can be performed.
The fixed-channel single conversion is automatically selected, irrespective of the ADMOD0<RE-
Top-priority AD conversion activated while top-priority AD conversion is under way is ignored.
Note:Top-priority A/D conversion interrupt cannot generate DMA transfer request.To generate DMA trans-
Top-priority AD conversion
peat conversation mode.
sion is completed, ADMOD0<EOCFN> is set to "1". ADMOD0<ADBFN> is not cleared to "0". It re-
mains at "1". The timing with which the conversion completion interrupt request (INTAD) is gener-
ated can be selected by setting ADMOD0<ITM> to an appropriate setting. <EOCFN> is set with
the same timing as this interrupt INTAD is generated.
peat conversion mode.
AD scan conversion is completed, ADMOD0<EOCFN> is set to "1", and the conversion comple-
tion interrupt request (INTAD) is generated. ADMOD0<ADBFN> is cleared to "0". It remains at
"1". <EOCFN> is cleared to "0" upon read.
fer request, please use A/D conversion completion interrupt (INTAD).
If ADMOD0<REPEAT, SCAN> is set to "10", AD conversion is performed in fixed channel re-
In this mode, AD conversion is performed repeatedly for one channel selected. After AD conver-
By reading <EOCFN>, it is cleared to "0".
If ADMOD0<REPEAT, SCAN> is set to "11", AD conversion is performed in the channel scan re-
In this mode, AD conversion is performed repeatedly for a scan channel selected. Each time one
Fixed channel repeat conversion mode
Channel scan repeat conversion mode
Page 691
TMPM364F10FG