IDT72V51333L7-5BB8 IDT, Integrated Device Technology Inc, IDT72V51333L7-5BB8 Datasheet - Page 24

IC FLOW CTRL MULTI QUEUE 256-BGA

IDT72V51333L7-5BB8

Manufacturer Part Number
IDT72V51333L7-5BB8
Description
IC FLOW CTRL MULTI QUEUE 256-BGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT72V51333L7-5BB8

Configuration
Dual
Density
512Kb
Access Time (max)
4ns
Word Size
18b
Organization
4Kx18x8
Sync/async
Synchronous
Expandable
Yes
Bus Direction
Uni-Directional
Package Type
BGA
Clock Freq (max)
133MHz
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
3.15V
Operating Supply Voltage (max)
3.45V
Supply Current
100mA
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
256
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
72V51333L7-5BB8
devices connected in expansion. In expansion mode one device will be set
as the Master, MAST input tied HIGH, all other devices will have MAST tied
LOW. The master device is the first device to take control of the PAEn bus and
place the PAE status of its queues onto the bus on the first rising edge of RCLK
after the MRS input goes HIGH once a Master Reset is complete. The
ESYNC (PAE sync pulse) output of the first device (master device), will be
HIGH for one cycle of RCLK indicating that it is has control of the PAEn bus for
that cycle.
device assuming control of the PAEn bus on the next RCLK cycle. This token
IDT72V51333/72V51343/72V51353 3.3V, MULTI-QUEUE FLOW-CONTROL DEVICES
(8 QUEUES) 18 BIT WIDE CONFIGURATION 589,824, 1,179,648 and 2,359,296 bits
The device also passes a “token” onto the next device in the chain, the next
24
passing is done via the EXO outputs and EXI inputs of the devices (“PAEn
Expansion Out” and “PAEn Expansion In”). The EXO output of the first device
connecting to the EXI input of the second device in the chain, the EXO of the
second device connects to the EXI of the third device and so on. The EXO of
the final device in a chain connects to the EXI of the first device, so that once the
PAEn bus has cycled through all devices control is again passed to the first
device. The EXO output of a device will be HIGH for the RCLK cycle it has control
of the bus.
Please refer to Figure 25, PAEn Bus – Polled Mode for timing information.
COMMERCIAL AND INDUSTRIAL
TEMPERATURE RANGES