IDT72P51777L7-5BBI IDT, Integrated Device Technology Inc, IDT72P51777L7-5BBI Datasheet - Page 32

no-image

IDT72P51777L7-5BBI

Manufacturer Part Number
IDT72P51777L7-5BBI
Description
IC FLOW CTRL 40BIT 376-BGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT72P51777L7-5BBI

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
72P51777L7-5BBI

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT72P51777L7-5BBI
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
STANDARD MODE OPERATION
WRITE QUEUE SELECTION AND WRITE OPERATION
(STANDARD MODE)
configured up to a maximum of 128 queues which data can be written via a
common write port using the data inputs (Din), write clock (WCLK) and write
enable (WEN). The queue to be written is selected by the address present on
the write address bus (WRADD) during a rising edge on WCLK while write
address enable (WADEN) is HIGH. The state of WEN does not impact the queue
selection. The queue selection requires 4 WCLK cycle. All subsequent data
writes will be to this queue until another queue is selected.
device. The write port is designed such that 100% bus utilization can be
obtained. This means that data can be written into the device on every WCLK
rising edge including the cycle that a new queue is being addressed.
TABLE 8 — WRITE ADDRESS BUS, WRADD[7:0]
IDT72P51767/72P51777 1.8V, MULTI-QUEUE FLOW-CONTROL DEVICES
(128 QUEUES) 40 BIT WIDE CONFIGURATION 5,898,240 and 11,796,480 bits
The IDT72P51767/72P51777 multi-queue flow-control devices can be
Standard mode operation is defined as individual words will be written to the
Quadrant
Operation WCLK WADEN FSTR
Queue
Select
Select
PAFn
Write
Status Word
1
0
Address
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
0
1
32
SDR Write Queue Select, Write Operation and Full flag Operation). WADEN
goes high signaling a change of queue (clock cycle “A”). The address on
WRADD at that time determines the next queue. Data presented during that
cycle, will be written to the active (each) queue, provided WEN is LOW. If WEN
is HIGH (inactive), data will not be written in a queue. The write port discrete
full flag will update to show the full status of the newly selected queue. Data present
on the data input bus (Din), can be written into the newly selected queue on the
rising edge of WCLK a change of queue, provided WEN is LOW and the queue
is not full. If the selected queue is full at the point of its selection, any writes to that
queue will be prevented. Data cannot be written into a full queue.
Operation, and Figure 45, Full Flag Timing in Expansion Configuration for
timing diagrams.
Queue Status on PAFn Bus
Q0 : Q7 → PAF0 : PAF7
Q8 : Q15 → PAF0 : PAF7
Q16 : Q23 → PAF0 : PAF7
Q24 : Q31 → PAF0 : PAF7
Q32 : Q39 → PAF0 : PAF7
Q40 : Q47 → PAF0 : PAF7
Q48 : Q55 → PAF0 : PAF7
Q56 : Q63 → PAF0 : PAF7
Q64 : Q71 → PAF0 : PAF7
Q72 : Q79 → PAF0 : PAF7
Q80 : Q87 → PAF0 : PAF7
Q88 : Q95 → PAF0 : PAF7
Q96 : Q103 → PAF0 : PAF7
Q104 : Q111 → PAF0 : PAF7
Q112 : Q119 → PAF0 : PAF7
Q120 : Q127 → PAF0 : PAF7
Changing queues requires 4 WCLK cycles on the write port (see Figure 42,
Refer to Figure 42, SDR Write Queue Select, Write Operation and Full flag
Device Select
(Compared to
ID2,1,0)
Device Select
(Compared to
ID2,1,0)
7 6 5
7 6 5
WRADD[7:0]
Write Queue Address
(6 bits = 64 Queues
7 bits = 128 Queues)
4 3 2
4
X
3 2 1 0
Status Word
Address
6724
1 0
COMMERCIAL AND INDUSTRIAL
drw11
TEMPERATURE RANGES
FEBRUARY 11, 2009

Related parts for IDT72P51777L7-5BBI