ST7FLITE20F1B6 STMicroelectronics, ST7FLITE20F1B6 Datasheet - Page 150

IC MCU 8BIT 8K FLASH 20-DIP

ST7FLITE20F1B6

Manufacturer Part Number
ST7FLITE20F1B6
Description
IC MCU 8BIT 8K FLASH 20-DIP
Manufacturer
STMicroelectronics
Series
ST7r
Datasheets

Specifications of ST7FLITE20F1B6

Core Processor
ST7
Core Size
8-Bit
Speed
8MHz
Connectivity
SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
15
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
384 x 8
Voltage - Supply (vcc/vdd)
2.4 V ~ 5.5 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-DIP (0.300", 7.62mm)
Processor Series
ST7FLITE2x
Core
ST7
Data Bus Width
8 bit
Development Tools By Supplier
ST7FLITE-SK/RAIS, ST7MDT10-DVP3, ST7MDT10-EMU3, STX-RLINK
For Use With
497-5858 - EVAL BOARD PLAYBACK ST7FLITE497-5517 - EVAL BOARD 1PHASE ENERGY METER497-5049 - KIT STARTER RAISONANCE ST7FLITE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST7FLITE20F1B6
Manufacturer:
ST
0
Function Descriptions
9.1.8 LITE TIMER (LT)
This software library consists of the following functions for LT.
Note: By default this function also sets the timebase to 1ms. To change the timebase to 2ms,
Table 97. LT_WDG_Enable
Note: This function works only for ST7FLITE0 and ST7SUPERLITE.
150/235
Function Name
Function Prototype
Behaviour Description
Input Parameter
Output Parameters
Required Preconditions
Functions called
Postconditions
See also
Function Name
Function Prototype
Behaviour Description
Input Parameter
Output Parameters
Required Preconditions
Functions called
Postconditions
See also
you can use the LT_TB function.
1) Present in ST7FLITE0 and ST7SUPERLITE.
2) Present in ST7FLITE1/2/3 and ST7FDALI.
Void LT_Init(Lt_InitParameter InitValue)
Initialization of the LT, by default sets Timebase as 1ms,
watchdog and interrupts disabled. It initializes the input
capture flag. To change this default configuration, you can
pass one or more input parameters by logically ORing
them together.
LT_ICAP_IT_ENABLE
enables input capture interrupt
LT_TB_IT_ENABLE
enables Timebase interrupt
LT_TB1_IT_ENABLE
enables Timebase1 interrupt
LT_TB2_IT_ENABLE
enables Timebase2 interrupt
LT_DEFAULT
sets default configuration
None
None
None
LT is configured as desired
LT_TB
LT_WDG_Enable
Void LT_WDG_Enable(void)
Enables the watchdog.
None
None
None
None
Watchdog is enabled. You can call LT_WDG_Reset to de-
lay or force the watchdog reset.
LT_WDG_Reset
LT_Init
1)
2)
2)

Related parts for ST7FLITE20F1B6