Specifications of S9S12P128J0MFT

Core Processor
HCS12
Core Size
16-Bit
Speed
32MHz
Connectivity
CAN, SCI, SPI
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
34
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Eeprom Size
4K x 8
Ram Size
6K x 8
Voltage - Supply (vcc/vdd)
1.72 V ~ 5.5 V
Data Converters
A/D 10x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
48-QFN Exposed Pad
Controller Family/series
S12
No. Of I/o's
34
Ram Memory Size
6KB
Cpu Speed
32MHz
No. Of Timers
1
Rohs Compliant
Yes
Processor Series
S12P
Core
HCS12
3rd Party Development Tools
EWHCS12
Development Tools By Supplier
KIT33812ECUEVME, DEMO9S12PFAME
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Upon clearing CCIF to launch the Program P-Flash command, the Memory Controller will program the
data words to the supplied global address and will then proceed to verify the data words read back as
expected. The CCIF flag will set after the Program P-Flash operation has completed.
13.4.5.6
The Program Once command restricts programming to a reserved 64 byte field (8 phrases) in the
nonvolatile information register located in P-Flash. The Program Once reserved field can be read using the
Read Once command as described in
once since the nonvolatile information register in P-Flash cannot be erased. The Program Once command
must not be executed from the Flash block containing the Program Once reserved field to avoid code
runaway.
Freescale Semiconductor
Register
FSTAT
Program Once Command
1. Global address [2:0] must be 000
CCOBIX[2:0]
CCOBIX[2:0]
Table 13-39. Program P-Flash Command FCCOB Requirements
MGSTAT1
MGSTAT0
ACCERR
Error Bit
Table 13-41. Program Once Command FCCOB Requirements
FPVIOL
011
100
101
000
001
010
011
100
101
Table 13-40. Program P-Flash Command Error Handling
S12P-Family Reference Manual, Rev. 1.13
Set if CCOBIX[2:0] != 101 at command launch
Set if command not available in current mode (see
Set if an invalid global address [17:0] is supplied
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the global address [17:0] points to a protected area
Set if any errors have been encountered during the verify operation
Set if any non-correctable errors have been encountered during the verify
operation
Section
Program Once phrase index (0x0000 - 0x0007)
0x07
13.4.5.4. The Program Once command must only be issued
Program Once word 0 value
Program Once word 1 value
Program Once word 2 value
Program Once word 3 value
Word 1 program value
Word 2 program value
Word 3 program value
FCCOB Parameters
FCCOB Parameters
Error Condition
Not Required
128 KByte Flash Module (S12FTMRC128K1V1)
Table
13-27)