MC908GT16CBE Freescale Semiconductor, MC908GT16CBE Datasheet - Page 139

IC MCU 16K FLASH 8MHZ SPI 42SDIP

MC908GT16CBE

Manufacturer Part Number
MC908GT16CBE
Description
IC MCU 16K FLASH 8MHZ SPI 42SDIP
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MC908GT16CBE

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM
Number Of I /o
36
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
42-DIP (0.600", 15.24mm)
Controller Family/series
HC08
No. Of I/o's
34
Ram Memory Size
512Byte
Cpu Speed
8MHz
No. Of Timers
2
Embedded Interface Type
I2C, SCI, SPI
Rohs Compliant
Yes
Processor Series
HC08GT
Core
HC08
Data Bus Width
8 bit
Data Ram Size
512 B
Interface Type
SCI, SPI
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
30
Number Of Timers
4
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Development Tools By Supplier
FSICEBASE, DEMO908GZ60E, M68CBL05CE, M68EML08GPGTE
Minimum Operating Temperature
- 40 C
On-chip Adc
8 bit, 8 Channel
Package
42SPDIP
Family Name
HC08
Maximum Speed
8 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
13.2.3.3 Low-Voltage Inhibit Reset
A low-voltage inhibit (LVI) reset is an internal reset caused by a drop in the power supply voltage to the
LVI
An LVI reset:
13.2.3.4 Illegal Opcode Reset
An illegal opcode reset is an internal reset caused by an opcode that is not in the instruction set. An illegal
opcode reset sets the ILOP bit in the SIM reset status register.
If the stop enable bit, STOP, in the CONFIG1 register is a 0, the STOP instruction causes an illegal
opcode reset.
13.2.3.5 Illegal Address Reset
An illegal address reset is an internal reset caused by opcode fetch from an unmapped address. An illegal
address reset sets the ILAD bit in the SIM reset status register.
A data fetch from an unmapped address does not generate a reset.
13.2.4 SIM Reset Status Register
This read-only register contains flags to show reset sources. All flag bits are automatically cleared
following a read of the register. Reset service can read the SIM reset status register to clear the register
after power-on reset and to determine the source of any subsequent reset.
The register is initialized on power-up as shown with the POR bit set and all other bits cleared. During a
POR or any other internal reset, the RST pin is pulled low. After the pin is released, it will be sampled 32
CGMXCLK cycles later. If the pin is not above a V
in addition to whatever other bits are set.
Freescale Semiconductor
TRIPF
Holds the clocks to the CPU and modules inactive for an oscillator stabilization delay of 4096
CGMXCLK cycles after the power supply voltage rises to the LVI
Drives the RST pin low for as long as V
stabilization delay
Releases the RST pin 32 CGMXCLK cycles after the oscillator stabilization delay
Releases the CPU to begin the reset vector sequence 64 CGMXCLK cycles after the oscillator
stabilization delay
Sets the LVI bit in the SIM reset status register
voltage.
Only a read of the SIM reset status register clears all reset flags. After
multiple resets from different sources without reading the register, multiple
flags remain set.
MC68HC908GT16 • MC68HC908GT8 • MC68HC08GT16 Data Sheet, Rev. 5.0
DD
NOTE
is below the LVI
IH
at that time, then the PIN bit in the SRSR may be set
TRIPR
voltage and during the oscillator
TRIPR
voltage
Resets
139