M30624FGAFP#U3 Renesas Electronics America, M30624FGAFP#U3 Datasheet - Page 370

IC M16C MCU FLASH 100QFP

M30624FGAFP#U3

Manufacturer Part Number
M30624FGAFP#U3
Description
IC M16C MCU FLASH 100QFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/60r
Datasheets

Specifications of M30624FGAFP#U3

Core Processor
M16C/60
Core Size
16-Bit
Speed
16MHz
Connectivity
SIO, UART/USART
Peripherals
DMA, PWM, WDT
Number Of I /o
85
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
20K x 8
Voltage - Supply (vcc/vdd)
4.2 V ~ 5.5 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-QFP
For Use With
867-1000 - KIT QUICK START RENESAS 62PM3062PT3-CPE-3 - EMULATOR COMPACT M16C/62P/30P
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30624FGAFP#U3M30624FGAFP
Manufacturer:
MITSUBIS
Quantity:
1
Company:
Part Number:
M30624FGAFP#U3M30624FGAFP
Manufacturer:
RENESAS
Quantity:
20 000
Company:
Part Number:
M30624FGAFP#U3M30624FGAFP#D3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30624FGAFP#U3M30624FGAFP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30624FGAFP#U3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Timer B
2.3.7 Precautions for Timer B (pulse period/pulse width measurement mode)
(1) The timer Bi interrupt request bit goes to “1” when an effective edge of a measurement pulse
(2) If the timer overflow occurs simultaneously with the input of a measurement pulse, and if the
(3) When reset, the timer Bi overflow flag goes to “1”. This flag can be set to “0” by writing to the
(4) Use the timer Bi interrupt request bit to detect only overflows. Use the timer Bi overflow flag
(5) When the first effective edge is input after a count is started, an indeterminate value is trans-
(6) The value of the counter is indeterminate at the beginning of a count. Therefore, the timer Bi
(7) If changing the measurement mode select bits are set after a count is started, the timer Bi
(8) If the input signal to the TBi
(9) For pulse width measurement, pulse widths are successively measured. Use software to
is input or timer Bi is overflowed. The factor of interrupt request can be determined by use of
the timer Bi overflow flag within the interrupt routine.
interrupt factor cannot be determined from the timer Bi overflow flag, connect the timers and
count the number of overflows.
timer Bi mode register when the count start flag is “1”.
only to determine the interrupt factor within the interrupt routine.
ferred to the reload register. At this time, timer Bi interrupt request is not generated.
overflow flag may go to “1” and timer Bi interrupt request may be generated during the inter-
val between a count start and an effective edge input.
interrupt request bit goes to “1”. Note that the timer Bi interrupt request bit does not change if
the same value as before is written to the measurement mode select bits.
performed in some cases. It is recommended to see that measurements fall within a specific
range by use of software.
check whether the measurement result is an “H” level width or an “L” level width.
IN
pin is affected by noise, precise measurement may not be
SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER
M16C / 62A Group
Mitsubishi microcomputers
2-51

Related parts for M30624FGAFP#U3