MC912D60ACPV8 Freescale Semiconductor, MC912D60ACPV8 Datasheet - Page 355

no-image

MC912D60ACPV8

Manufacturer Part Number
MC912D60ACPV8
Description
IC MCU 6K FLASH 8MHZ 112-LQFP
Manufacturer
Freescale Semiconductor
Series
HC12r
Datasheet

Specifications of MC912D60ACPV8

Core Processor
CPU12
Core Size
16-Bit
Speed
8MHz
Connectivity
CAN, MI Bus, SCI, SPI
Peripherals
POR, PWM, WDT
Number Of I /o
68
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 16x8/10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
112-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC912D60ACPV8
Manufacturer:
FREESCALE
Quantity:
5 530
Part Number:
MC912D60ACPV8
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
MC912D60ACPV8
Manufacturer:
QFP
Quantity:
748
Part Number:
MC912D60ACPV8
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC912D60ACPV8
Manufacturer:
FREESCALE
Quantity:
20 000
18.5.2 IDLE Mode
18.5.3 RUN Mode
18.6 ATD Operation In Different MCU Modes
18.6.1 STOP Mode
MC68HC912D60A — Rev. 3.1
Freescale Semiconductor
NOTE:
can be performed. Note that powering up the module does not reset the
module since the register file is not initialized.
In power down mode, the control and result registers are still accessible.
IDLE mode for the ATD module is defined as the state where the ATD
module is powered up and ready to perform an A/D conversion, but not
actually performing a conversion at the present time. Access to all
control, status, and result registers is available. The module is
consuming near maximum power.
When not active, the sample-and-hold and analog-to-digital sub-
modules disable the clocks at their inputs to conserve power. The analog
electronics still draw quiescent current.
RUN mode for the ATD module is defined as the state where the ATD
module is powered up and currently performing an A/D conversion.
Complete assess to all control, status and result registers is available.
The module is consuming maximum power.
Asserting Stop causes the ATD module to power down. The digital clocks
are disabled and the analog quiescent current draw is turned off; this
places the module into its power down state and is equivalent to clearing
the ADPU control bit in ATDCTL2.
Analog-to-Digital Converter
ATD Operation In Different MCU Modes
Analog-to-Digital Converter
Technical Data
355

Related parts for MC912D60ACPV8