SAK-XC161CS-32F40F BB-A Infineon Technologies, SAK-XC161CS-32F40F BB-A Datasheet - Page 79

no-image

SAK-XC161CS-32F40F BB-A

Manufacturer Part Number
SAK-XC161CS-32F40F BB-A
Description
IC MCU 16BIT 256KB TQFP-144-19
Manufacturer
Infineon Technologies
Series
XC16xr
Datasheet

Specifications of SAK-XC161CS-32F40F BB-A

Core Processor
C166SV2
Core Size
16-Bit
Speed
40MHz
Connectivity
CAN, EBI/EMI, I²C, SPI, UART/USART
Peripherals
PWM, WDT
Number Of I /o
99
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
2.35 V ~ 2.7 V
Data Converters
A/D 12x8/10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
144-LFQFP
Data Bus Width
16 bit
Data Ram Size
12 KB
Interface Type
ASC, CAN, IIC, SSC
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
99
Number Of Timers
9
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 12 Channel
Packages
PG-TQFP-144
Max Clock Frequency
40.0 MHz
Sram (incl. Cache)
12.0 KByte
Can Nodes
2
A / D Input Lines (incl. Fadc)
12
Program Memory
256.0 KByte
For Use With
MCBX167-NET - BOARD EVAL INFINEON CAN/ETHRNTMCBXC167-BASIC - BOARD EVAL BASIC INFINEON XC16X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
KX161CS32F40FBBANT
KX161CS32F40FBBAXT
SAKXC161CS32F40FBBAT
SP000098775
SP000224544
XC161CS-32F
Derivatives
Electrical Parameters
Bus Cycle Control via READY Input
The duration of an external bus cycle can be controlled by the external circuitry via the
READY input signal. The polarity of this input signal can be selected.
Synchronous READY permits the shortest possible bus cycle but requires the input
signal to be synchronous to the reference signal CLKOUT.
Asynchronous READY puts no timing constraints on the input signal but incurs one
waitstate minimum due to the additional synchronization stage. The minimum duration
of an asynchronous READY signal to be safely synchronized must be one CLKOUT
period plus the input setup time.
An active READY signal can be deactivated in response to the trailing (rising) edge of
the corresponding command (RD or WR).
If the next following bus cycle is READY-controlled, an active READY signal must be
disabled before the first valid sample point for the next bus cycle. This sample point
depends on the programmed phases of the next following cycle.
Data Sheet
77
V1.2, 2006-08