AT25DF081A-MH-T Atmel, AT25DF081A-MH-T Datasheet - Page 22

no-image

AT25DF081A-MH-T

Manufacturer Part Number
AT25DF081A-MH-T
Description
IC FLASH 8MBIT SPI 8UDFN
Manufacturer
Atmel
Datasheet

Specifications of AT25DF081A-MH-T

Format - Memory
FLASH
Memory Type
DataFLASH
Memory Size
8M (4096 pages x 256 bytes)
Speed
100MHz
Interface
SPI, RapidS
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-UDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
22
Table 9-2.
Essentially, if the SPRL bit of the Status Register is in the logical “0” state (Sector Protection Registers are not
locked), then writing a 00h to the first byte of the Status Register will perform a Global Unprotect without changing
the state of the SPRL bit. Similarly, writing a 7Fh to the first byte of the Status Register will perform a Global Protect
and keep the SPRL bit in the logical “0” state. The SPRL bit can, of course, be changed to a logical “1” by writing an
FFh if software-locking or hardware-locking is desired along with the Global Protect.
If the desire is to only change the SPRL bit without performing a Global Protect or Global Unprotect, then the sys-
tem can simply write a 0Fh to the first byte of the Status Register to change the SPRL bit from a logical “1” to a
logical “0” provided the WP pin is deasserted. Likewise, the system can write an F0h to change the SPRL bit from
a logical “0” to a logical “1” without affecting the current sector protection status (no changes will be made to the
Sector Protection Registers).
When writing to the first byte of the Status Register, bits five, four, three, and two will not actually be modified but
will be decoded by the device for the purposes of the Global Protect and Global Unprotect functions. Only bit
seven, the SPRL bit, will actually be modified. Therefore, when reading the first byte of the Status Register, bits
five, four, three, and two will not reflect the values written to them but will instead indicate the status of the WP pin
and the sector protection status. Please refer to
details on the Status Register format and what values can be read for bits five, four, three, and two.
Atmel AT25DF081A
State
WP
1
Current
SPRL
Value
1
Valid SPRL and Global Protect/Unprotect Conditions (Continued)
New Write Status
Register Byte 1
7 6 5 4 3 2 1 0
0 x 0 0 0 0 x x
0 x 0 0 0 1 x x
0 x 1 1 1 0 x x
0 x 1 1 1 1 x x
1 x 0 0 0 0 x x
1 x 0 0 0 1 x x
1 x 1 1 1 0 x x
1 x 1 1 1 1 x x
Data
Bit
Protection Operation
No change to the current protection level. All sectors currently protected will remain
protected, and all sectors currently unprotected will remain unprotected.
The Sector Protection Registers are soft-locked and cannot be changed when the
current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur.
However, the SPRL bit can be changed back to a 0 from a 1 since the WP pin is
HIGH. To perform a Global Protect/Unprotect, the Write Status Register command
must be issued again after the SPRL bit has been changed from a 1 to a 0.
“Read Status Register” on page 31
and
Table 11-1 on page 31
8715B–SFLSH–8/10
SPRL
Value
New
0
0
0
0
0
1
1
1
1
1
for