80.91.0.240.0000 FINDER, 80.91.0.240.0000 Datasheet - Page 105

TIMER, MULTIFUNCTION

80.91.0.240.0000

Manufacturer Part Number
80.91.0.240.0000
Description
TIMER, MULTIFUNCTION
Manufacturer
FINDER
Datasheet

Specifications of 80.91.0.240.0000

Contact Configuration
SPCO
Nom Input Voltage
240V
Delay Time Range
0.1s To 20h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
240V
Coil Voltage Max
240V
L/+
N/–
Wiring diagram
Multi-function
without signal START
L/+
N/–
with signal START (S)
Mono-function
without signal START
L/+
N/–
with signal START
FUNCTIONS
L/+
N/–
L/+
N/–
A2
A2
A2
A2
A1
A1
A1
A1
A2
A1
B1
B1
*
*
S
S
18
18
18
17
18 28
18
15
82.01
82.01
15
82.11
82.21
82.31
82.82
82.41
15
15
16
16
16
16
Without signal Start= Start via contact in supply line (A1).
With signal Start = Start via contact into control terminal (B1).
U = Supply Voltage
S = Signal switch
C = Output contact
82.21
82.82
82.41
* A voltage other than the supply voltage can be applied to the command START (B1).
82.01
82.11
82.31
Type
Example: A1 - A2 = 230 V AC/B1 - A2 = 24 V AC
U
C
U
C
U
C
U
C
U
C
U
C
U
S
C
U
U
S
C
T
T
T
T
T
T
T
T
T
LED
T
T
T
T
Tu= 60 ms
T
T
82.01
82.11
82.21
82.31
82.41
82.82
Relay
type
t<T
t<T
T
T
t>T
t>T
t<T
t<T
t<T
t<T
t<T
t<T
Supply voltage
82 Series - Modular Timers 5 A
ON
ON
ON
ON
(AI)
Apply power to timer. Output contacts transfer after preset time
has elapsed. Reset occurs when power is removed.
(DI)
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(BE)
Power is permenently applied to the timer.
The output contacts transfer immediately on closure of the Signal
Switch (S). Opening the Signal Switch initiates the preset delay,
after which time the output contacts reset.
(AI)
Apply power to timer. Output contacts transfer after preset time
has elapsed. Reset occurs when power is removed.
(DI)
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(SW)
Apply power to timer. Output contacts transfer immediately and
cycle between ON and OFF for as long as power is applied.
The ratio is 1:1 (time on = time off).
(SD)
Apply power to timer. The star contact ( ) closes immediately.
After preset delay has elapsed the star contact ( ) resets.
After a further fixed time of ~60 ms the delta contact (
closes and remains in that position, until reset on power off.
(BE)
Power is permenently applied to the timer.
The output contacts transfer immediately on closure of the Signal
Switch (S). Opening the Signal Switch initiates the preset delay,
after which time the output contacts reset.
(SW)
Apply power to timer. Output contacts transfer immediately and
cycle between ON and OFF for as long as power is applied.
The ratio is 1:1 (time on = time off).
ON delay.
ON pulse.
ON delay.
ON pulse.
Signal OFF delay.
Signal OFF delay.
Star - delta.
Symmetrical recycler: ON start.
Symmetrical recycler: ON start.
Closed (
Closed (
NO output
contact
Closed
Open
)
)
15 - 18
15 - 16
17 - 28
17 - 18
Open
Contacts
15 - 16
15 - 18
17 - 18
17 - 28
)
Closed
103
82

Related parts for 80.91.0.240.0000