80.91.0.240.0000 FINDER, 80.91.0.240.0000 Datasheet - Page 116

TIMER, MULTIFUNCTION

80.91.0.240.0000

Manufacturer Part Number
80.91.0.240.0000
Description
TIMER, MULTIFUNCTION
Manufacturer
FINDER
Datasheet

Specifications of 80.91.0.240.0000

Contact Configuration
SPCO
Nom Input Voltage
240V
Delay Time Range
0.1s To 20h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
240V
Coil Voltage Max
240V
86
114
N/–
N/–
Wiring diagram
with signal START
FUNCTIONS
without signal START
B 1 A2
B1 A2
10
10
34
L/+(-)
A2
34
A2
9
9
10
10
32
32
31
31
8
8
A1
24
11
11
24
7
7
21
21
22
22
U
6
6
5
5
14
14
11
11
A2
3
3
1
1
12
12
N/-(+)
A1
A1
4
4
2
2
L/+
L/+
Type 86.60
Without signal Start= Start via contact in supply line (A1).
With signal Start = Start via contact into control terminal (B1).
3
86.10
86.20
3
3
3
3
3
3
3
U = Supply Voltage
S = Signal switch
C = Output Contact
Type
Type
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
U
C
U
C
U
C
U
C
U
C
U
C
U
S
C
U
C
U
S
C
S
U
S
C
T
T
T
T
T
T
T
T
T
T
T
T
Green (86.60 only)
T
T
T
T
T
T
T
T
t<T
t<T
T
T
T
T
T
T
t<T
LED
t<T
T
t<T
t<T
t<T
t<T
(SP)
Apply power to timer. Output contacts transfer after time T has
elapsed and cycle between OFF and ON for as long as power
is applied. The ratio is 1:1 (time on = time off).
(AI)
Apply power to timer. Output contacts transfer after preset time
has elapsed. Reset occurs when power is removed.
(DI)
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(AI)
Apply power to timer. Output contacts transfer after preset time
has elapsed. Reset occurs when power is removed.
(SW)
Apply power to timer. Output contacts transfer immediately and
cycle between ON and OFF for as long as power is applied.
The ratio is 1:1 (time on = time off).
(DI)
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(BE)
Power is permenently applied to the timer.
The output contacts transfer immediately on closure of the Signal
Switch (S). Opening the Signal Switch initiates the preset delay,
after which time the output contacts reset.
(DE)
Power is permenently applied to the timer.
On momentary or maintained closure of Signal Switch (S),
the output contacts transfer, and remain so for the duration of
the preset delay, after which they reset.
(EE)
Power is permenently applied to the timer.
On opening of the Signal Switch (S) the output contacts transfer,
and remain so for the duration of the preset delay, after which
they reset.
(FE)
Power is permenently applied to the timer.
Both the opening and closing of the Signal Switch (S) initiates
the transfer of the output contacts. In both instances the contacts
reset after the delay period has elapsed.
Yellow
ON pulse.
ON delay.
ON delay.
ON pulse.
Symmetrical recycler: OFF start.
Signal ON pulse + OFF pulse.
Signal OFF pulse.
Signal OFF delay.
Signal ON pulse.
Symmetrical recycler: ON start.
86 Series - Timer Modules
voltage
Supply
OFF
ON
ON
NO output
contact
Closed
Open
Open

Related parts for 80.91.0.240.0000