CES-A-BBA EUCHNER, CES-A-BBA Datasheet - Page 10

ACTUATOR

CES-A-BBA

Manufacturer Part Number
CES-A-BBA
Description
ACTUATOR
Manufacturer
EUCHNER
Datasheet

Specifications of CES-A-BBA

External Depth
40.5mm
External Length / Height
131mm
Operating Temperature Max
55°C
Operating Temperature Min
-0°C
Non-Contact Safety Switches CES/CEM
Evaluation unit CES-A-ABA...
Dimension drawing
Notes on the electrical connection
10
24V 0V
TST
H1
CES
13
Housing for DIN rail mounting, IP 20
Relay output
1 read head can be connected
In combination with read head CES-A-L... and actuator CES-A-B..
22,5
OUT
H2
14
All the electrical connections must either be isolated from the mains supply by
a safety transformer according to EN/IEC 61558 with limited output voltage in
the event of a fault, or by other equivalent isolation measures.
The plug-in and coded terminals on the evaluation unit enable the cable
connections to be pre-assembled and so facilitate rapid final installation.
The H1/H2, ERR and OUT connections are not short circuit-proof.
If a common power supply is used, all the inductive and capacitive loads (e.g.
contactors) connected to the power supply must be connected to appropriate
interference suppression units.
ERR
23
STATE
OUT
ERROR
GND
SH
24
Suitable for 35 mm DIN rail
according to EN 50022-35
114
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
Switching characteristics
2 safety outputs (relay outputs)
1 door monitoring output (semiconductor output,
not a safety output)
Notes on installation
The evaluation unit must be mounted in a control
cabinet with a minimum degree of protection of
IP 54. A snap-in element on the back of the
evaluation unit is used for fastening to the
standard rail (35 mm DIN rail).
Safety precautions
24 V
Read head Actuator
(actuator detected)
13
23
The evaluation unit has a redundant switching
design with self-monitoring. This means that
the safety system is still effective even if a
component fails.
The door monitoring output OUT is not fail-
safe (not a safety output).
To ensure safety, it is imperative that the
safety outputs 13/14 and 23/24 are
connected.
closed
14
24
OUT
Safety guard
Read head
operating distance)
24 V
(actuator not in
13
23
open
14
24
OUT