CES-A-BBA EUCHNER, CES-A-BBA Datasheet - Page 44

ACTUATOR

CES-A-BBA

Manufacturer Part Number
CES-A-BBA
Description
ACTUATOR
Manufacturer
EUCHNER
Datasheet

Specifications of CES-A-BBA

External Depth
40.5mm
External Length / Height
131mm
Operating Temperature Max
55°C
Operating Temperature Min
-0°C
Non-Contact Safety Switches CES/CEM
Dimension drawing CES-A-BBA
2 safety screws M4x14
included
Technical data
1) The dwell time is the time that the actuator must be inside or outside the operating distance.
Ordering table
Actuator CES-A-BBA / CES-A-BCA
Dimension drawing CES-A-BCA
2 safety screws M4x14
included
Parameters
Housing material
Flat seal material
Dimensions
Weight
Ambient temperature
Degree of protection
Installation position
Power supply
Dwell time
44
Cube-shaped design 42 x 25 mm
CES-A-BCA suitable for use in aggressive media
(e.g. acids, alkaline)
In combination with evaluation units CES-A-A...,
read head CES-A-LNA... and safety switches CES-A-C5...
CES-A-BBA
CES-A-BCA
Item
1)
CES-A-B 071840
32 ±0,1
32
42
42
48
± 0,10
Flat
seal
Flat
seal
(flat seal included)
CES-A-BBA
CES-A-BCA
CES-A-BCA
CES-A-BBA
CES-A-BCA
Active
face
Active
face
4,6
2
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
12
12
4,6
Fortron, reinforced thermoplastic, fully encapsulated
Plastic PE-HD without reinforcing, fully encapsulated
min.
-25
0.5
-25
Active
face
Active
face
Active face opposite read head
Fluororubber 75 FPM 4100
Inductive via read head
42 x 25 x 12
Value
0.02
IP67
typ.
Notes on installation
-
-
-
Actuator and read head must be fitted so
that:
CES-A-BCA: The flat seal provided must be
used during assembly.
The active faces (front faces) are at the
switch-on distance 0.8 x S
technical data) with the safety guard closed.
They are not used as a mechanical stop.
They are positively mounted on the safety
guard, e.g. by using the safety screws
included.
max.
+70
+50
-
a0
or closer (see
Order No.
071 840
088 786
Unit
mm
kg
°C
°C
s

Related parts for CES-A-BBA