ACTUATOR

CES-A-BBA

Manufacturer Part Number
CES-A-BBA
Description
ACTUATOR
Manufacturer
EUCHNER
Datasheet

Specifications of CES-A-BBA

External Depth
40.5mm
External Length / Height
131mm
Operating Temperature Max
55°C
Operating Temperature Min
-0°C
Non-Contact Safety Switches CES/CEM
Function test CES-A-AEA... (self-test)
On electromechanical safety switches or magnetic switches, the function test can be performed by cyclically opening the safety guard.
From safety category 2, according to IEC/EN 60204-1 : 1997 (sec. 9.4.2.4), a function test must be performed on the entire safety
system on start-up or after defined intervals.
The testing of the internal function of the safety switch CES is not necessary because the device monitors itself in real time. Wear on
an output contact (relay output) is detected by the device at the latest the next time the safety guard is opened. A short circuit in the
output cable is not detected by the device.
In addition, the entire safety circuit can be tested without opening the safety guard. For this purpose the opening of the safety guard
can be simulated by applying DC 24 V to the test input.
The safety outputs are switched off, enabling testing of the complete safety circuit. The diagnostic output DIA of the evaluation unit is
also set HIGH as a monitoring function.
When the test input is reset, the evaluation unit resets the diagnostic output DIA to LOW, the red LED switches off and normal operation
continues. This permits self-testing of the safety system without opening the safety guard.
LED indicators
System status table CES-A-AEA-04B
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
Flashes at approx. 1 Hz
4 flashes repeated after 1 s
STATE LED (green)
Flashes continuously
3 flashes repeated
Normal operation
at approx. 15 Hz
at approx. 4 Hz
Operating fault
Function test
Fault display
LED labels
after 1 s
Flashes
STATE
Setup
OUT
Off
On
On
On
Off
DIA
OUT LED (yellow)
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
LED color
Yellow
Green
Red
DIA LED (red)
Off
Off
Off
Off
Off
Off
On
On
On
On
State display (multifunction display using flashing modes)
Initial setup after delivery without jumper connected
to J1, J2
Teach-in operation
Acknowledgement of completion of teach-in operation
Self-test, duration approx. 10 seconds, is performed
Normal operation, not all monitored doors are closed
Normal operation, all monitored doors are closed
(After pressing the start button, for Manual start
operating mode)
Function test active (TST input = 24 V)
Component failure inside the device or actuator in
the operating distance for less than 0.5 s or
actuator CES-A-BMB in the inadmissible range
Configuration fault:
Teach-in operation must be performed again
Possible causes:
- State change during the teach-in operation
- None of the DIP switches in ON position
- DIP switch setting and
- DIP switch setting has been changed without
- The teach-in jumper (J1, J2) was fitted with power
- Connected feedback loop (Y1,Y2) present,
- 24 V signal present at the start button input (S)
Fault in feedback loop
State
after the application of the operating voltage U
connected configuration did not match during
teach-in operation
teach-in operation
supply switched on
although a feedback loop was not present during
teach-in
although teach-in was performed with "Automatic
start" operating mode
external fault (fault in the feedback loop)
TST input activated (function test active)
or internal device fault
Safety circuit closed
Operating fault,
Significance