CES-A-BBA EUCHNER, CES-A-BBA Datasheet - Page 18

ACTUATOR

CES-A-BBA

Manufacturer Part Number
CES-A-BBA
Description
ACTUATOR
Manufacturer
EUCHNER
Datasheet

Specifications of CES-A-BBA

External Depth
40.5mm
External Length / Height
131mm
Operating Temperature Max
55°C
Operating Temperature Min
-0°C
Non-Contact Safety Switches CES/CEM
Evaluation unit CES-A-AEA-04B
Dimension drawing
Notes on the electrical connection
18
Housing for DIN rail mounting, IP 20
Relay output
4 read heads can be connected
In combination with read head CES-A-L... and actuator CES-A-B..
All the electrical connections must either be isolated from the mains supply by
a safety transformer according to EN/IEC 61558 with limited output voltage in
the event of a fault, or by other equivalent isolation measures.
The connections H1a/H1b ... H4a/H4b are not short circuit-proof.
If a common power supply is used, all the inductive and capacitive loads (e.g.
contactors) connected to the power supply must be connected to appropriate
interference suppression units.
45
Suitable for 35 mm DIN rail
according to EN 50022-35
114
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
Switching characteristics
2 safety outputs (relay outputs)
4 door monitoring outputs (semiconductor
outputs, not safety outputs)
Notes on installation
The evaluation unit must be mounted in a control
cabinet with a minimum degree of protection of
IP 54. A snap-in element on the back of the
evaluation unit is used for fastening to the
standard rail (35 mm DIN rail).
Safety precautions
Read head 1 Actuator 1
24 V
24 V
24 V
24 V
The evaluation unit has a redundant
switching design with self-monitoring. This
means that the safety system is still effective
even if a component fails.
The door monitoring outputs O1 ... O4 are
not fail-safe (not safety outputs)
To ensure safety, both safety outputs 13/14
and 23/24 must always be evaluated.
13
23
(all actuators
detected)
closed
Safety guard
14
24
O1
O2
O3
O4
in the operating distance)
(e.g. actuator 1 not
Read head 1
24 V
24 V
24 V
24 V
13
23
open
14
24
O1
O2
O3
O4

Related parts for CES-A-BBA