NZ1HS-2131-M EUCHNER, NZ1HS-2131-M Datasheet

SAFETY SWITCH

NZ1HS-2131-M

Manufacturer Part Number
NZ1HS-2131-M
Description
SAFETY SWITCH
Manufacturer
EUCHNER
Datasheet

Specifications of NZ1HS-2131-M

Actuation Type
Lever
Operating Force Max
15N
Contact Voltage Ac Max
230V
Contact Voltage Dc Max
24V
Contact Current Ac Max
4A
Contact Current Dc Max
4A
Switch Terminals
Screw
Actuator Type
Lever Arm
Actuator Style
Lever
Safety Switches
NZ TZ
NZ TZ
More than safety.

Related parts for NZ1HS-2131-M

NZ1HS-2131-M Summary of contents

Page 1

Safety Switches More than safety ...

Page 2

... EUCHNER products are sold through a world-wide sales network of compe- tent partners. With our closeness to the customer and the guarantee of reliable solutions throughout the globe, we enjoy the confidence of cus- tomers all over the world ...

Page 3

Safety Switches NZ/TZ General About this catalog How can I find the right switch? Standards and approvals Function and technology used in safety switches Attaching safety switches Overview of the switching elements Safety Switches with Safety Function, Metal Housing Single ...

Page 4

General About this catalog The Safety Switches NZ/TZ catalog gives you an overview of our series NZ and TZ safety switches with metal housing. For numerous applications these switches are the right choice due to their robustness and long service ...

Page 5

... Electromechanical control circuit devices). If the requirements of this standard are met, conformity with the applicable laws and therefore with the Machinery directive is assumed. EUCHNER safety switches comply with the relevant standards for safety switchgear and therefore help you to comply with safety requirements during the design of your machinery ...

Page 6

General Attaining the Attaining the safety function safety function 11 Actuation by trip dog Actuation by cam Safety switches with separate actuator On safety switches with separate actuator, the actuating element is se- parate to the switch and is attached ...

Page 7

General Snap-action switching element On snap-action switching elements, the change from the completely closed state to the completely open state is made at a defined point result the switching point defined position unlike on slow-action ...

Page 8

General Guard locking Safety switches with separate actuator are available both with and without guard locking. Guard locking is a feature that prevents the unintentional opening of a door as long as there is a hazard. The door is locked ...

Page 9

General Attaching the safety switch TZ The safety switch TZ can be mounted in a large number of different installation positions. Often the switch is mounted horizontally on the roof of a machine or with a suspended actuating head. The ...

Page 10

General Electrical connection On switches with cable entry there is a large space envelope for making the electrical connection. Modern wiring concepts increasingly utilize plug-in connections. A switch with plug connectors can be easily replaced during servicing work. This configuration ...

Page 11

General Switching elements The switching elements used in our safety switches have a dedicated numbering system. A selection of switching elements is available depending on the switch type. In the following overview you can see which switching element is covered ...

Page 12

General 12 ...

Page 13

Safety Switches with Safety Function, Metal Housing Selection table for single hole fixing limit switches N1A and NB01 Actuating element N1AD N1AR N1ARL N1AW NB01D Actuating element N1AD N1AR N1ARL N1AW NB01D ...

Page 14

Safety Switches with Safety Function, Metal Housing Single hole fixing limit switch N1AD with chisel plunger Housing according to DIN 43693 LED optional Plug connector optional Exterior diaphragm optional Approach direction Horizontal Can be adjusted in 90°-steps. Exterior diaphragm (optional) ...

Page 15

Safety Switches with Safety Function, Metal Housing Cable entry M16 x 1.5 Exterior diaphragm Dimension drawings Dog ±0,1 26 ∅10 Cable entry 76 M16 x 1.5 ∅7 35 Wiring diagrams 508 514 ...

Page 16

Safety Switches with Safety Function, Metal Housing Single hole fixing limit switch N1AR with roller plunger Housing according to DIN 43693 Steel roller ∅ ∅ ∅ ∅ ∅ LED optional Plug connector optional Exterior diaphragm optional Bearing optional ...

Page 17

Safety Switches with Safety Function, Metal Housing Cable entry M16 x 1.5 Exterior diaphragm Dimension drawings Dog ±0,1 26 Cable entry 76 M16 x 1.5 ∅7 35 Wiring diagrams 508 514 ...

Page 18

Safety Switches with Safety Function, Metal Housing Single hole fixing limit switch N1ARL with extended roller plunger Housing according to DIN 43693 Steel roller ∅ ∅ ∅ ∅ ∅ Approach direction Horizontal Can be adjusted in 90°-steps. Switching ...

Page 19

Safety Switches with Safety Function, Metal Housing Single hole fixing limit switch N1AW with domed plunger Housing according to DIN 43693 LED optional Plug connector optional Approach direction Horizontal and vertical LED function display (optional) A function display is available ...

Page 20

Safety Switches with Safety Function, Metal Housing Single hole fixing limit switch NB01 With chisel plunger With roller plunger, steel roller ∅ ∅ ∅ ∅ ∅ Approach direction Horizontal Can be adjusted in 90°-steps. Switching elements (see also ...

Page 21

Safety Switches with Safety Function, Metal Housing Selection table for position switches NZ Actuating element Actuating element ...

Page 22

Safety Switches with Safety Function, Metal Housing Position switch NZ.WO with domed plunger Version B according to EN 50041 (hardened) LED optional Plug connector optional Approach direction Horizontal and vertical LED function display (optional) A function display is available for ...

Page 23

Safety Switches with Safety Function, Metal Housing 1) Plug connector SR6 6-pin + PE Dimension drawings Dog +1 40 ±0,1 30 5,3 5,3 For mating connectors see page 79 Wiring diagrams switch not activated 511/528H ...

Page 24

Safety Switches with Safety Function, Metal Housing Position switch NZ.RK with roller plunger Steel roller ∅ ∅ ∅ ∅ ∅ LED optional Plug connector optional Bearing optional Approach direction Horizontal Can be adjusted in 90°-steps. LED function display ...

Page 25

Safety Switches with Safety Function, Metal Housing Plug connector SR6 6-pin + PE Dimension drawings Dog +1 40 ±0,1 30 5,3 Wiring diagrams switch not activated 511/528H LED optional PE ...

Page 26

Safety Switches with Safety Function, Metal Housing Position switch NZ.RS with roller plunger Version C according to EN 50041 (steel roller ∅ 12 mm) LED optional Plug connector optional ATEX approval optional Approach direction Horizontal Can be adjusted in 90°-steps. ...

Page 27

Safety Switches with Safety Function, Metal Housing 1) Plug connector SR6 Plug connector SR6 angled 6-pin + PE 6-pin + PE Dimension drawings Dog Elbow adaptor not locked. Is fixed mounting by the customer. Adjustable max. 90° ...

Page 28

Safety Switches with Safety Function, Metal Housing Position switch NZ.RG with roller plunger Version C according to EN 50041 (plastic roller ∅ 12 mm) LED optional Plug connector optional Approach direction Horizontal Can be adjusted in 90°-steps LED function display ...

Page 29

Safety Switches with Safety Function, Metal Housing 1) Plug connector SR6 6-pin + PE Dimension drawings Dog +1 40 ±0,1 30 5,3 5,3 For mating connectors see page 79 Wiring diagrams switch not activated 511/528H ...

Page 30

Safety Switches with Safety Function, Metal Housing Position switch NZ.RL with roller plunger Steel roller ∅ ∅ ∅ ∅ ∅ LED optional Plug connector optional Approach direction Horizontal Can be adjusted in 90°-steps. LED function display (optional) A ...

Page 31

Safety Switches with Safety Function, Metal Housing Plug connector SR6 6-pin + PE Dimension drawings Dog +1 40 ±0,1 30 5,3 5,3 Wiring diagrams switch not activated 511/528H LED optional ...

Page 32

... NZ1HS-511-M NZ1HS-511L060-M 090 970 090 971 NZ1HS-528-M NZ1HS-528L060-M 090 972 090 760 NZ1HS-538-M NZ1HS-538L060-M 090 254 - NZ1HS-2121-M 090 973 - NZ1HS-2131-M 090 747 - NZ1HS-3131-M ATEX incl. 094 167 2) - cable gland NZ1HS-3131-M-EX 090 867 On request NZ2HS-511SVM5 090 868 On request NZ2HS-528SVM5 090 869 ...

Page 33

... Version Without LED 089 093 1) NZ2HS-511 C1630 On request Alternative wiring 090 852 NZ2HS-528 090 853 NZ2HS-538 086 574 NZ1HS-3131-8C-Ford / PT60577-101K01 077 391 3) NZ1HS-2131-9C-GMMF 073 508 NZ1HS-3131-9C-GMMF 091 264 NZ2HS-2121 090 146 NZ2HS-2131 090 856 NZ2HS-3131 3) Plug connector SR11 11-pin + ±0,1 30 5,3 ...

Page 34

Safety Switches with Safety Function, Metal Housing Position switch NZ.HB with roller lever arm Version A according to EN 50041 (plastic roller ∅ 18) LED optional Plug connector optional Approach direction Horizontal Switch head and lever arm can be adjusted ...

Page 35

Safety Switches with Safety Function, Metal Housing 1) Plug connector SR6 Plug connector SR6 angled 6-pin + PE 6-pin + PE Dimension drawings Dog +1 40 ±0,1 30 5,3 5,3 For mating connectors see page 79 Wiring diagrams switch not ...

Page 36

Safety Switches with Safety Function, Metal Housing Position switch NZ.PS with adjustable lever arm Steel roller ∅ ∅ ∅ ∅ ∅ 18 LED optional Plug connector optional Approach direction Horizontal Switch head and lever arm can be adjusted in 90° ...

Page 37

Safety Switches with Safety Function, Metal Housing Plug connector SR6 6-pin + PE Dimension drawings Wiring diagrams switch not activated 511 LED optional PE ...

Page 38

Safety Switches with Safety Function, Metal Housing Position switch NZ.PB with adjustable lever arm Plastic roller ∅ ∅ ∅ ∅ ∅ 18 Approach direction Horizontal Switch head and lever arm can be adjusted in 90° steps. Switching direction Right, left ...

Page 39

Safety Switches with Safety Function, Metal Housing Position switch NZ.RS.C1588 with roller plunger Version C according to EN 50041 (steel roller ∅ 12 mm) Exterior bellows (CR-based material) Approach direction Horizontal Switch head and lever arm can be adjusted in ...

Page 40

Safety Switches with Safety Function, Metal Housing Position switch NZ.HB.C569 with roller lever arm Large plastic roller ∅ ∅ ∅ ∅ ∅ LED optional Approach direction Horizontal Switch head and lever arm can be adjusted in 90° steps. ...

Page 41

Safety Switches with Separate Actuator, Metal Housing Selection table for safety switches NZ.VZ Version SB Protective plate, tamper protection on the switch head Connection M SVM5 C16-1 Connection SB M SVM5 C16 Thread ...

Page 42

Safety Switches with Separate Actuator, Metal Housing Safety switch NZ.VZ Housing according to EN 50041 Various cable entries Plug connector optional LED optional Approach direction Horizontal Can be adjusted in 90°-steps. LED function display (optional) A function display is available ...

Page 43

Safety Switches with Separate Actuator, Metal Housing Plug connector SR6 Plug connector MR8 6-pin + PE 7-pin + PE Dimension drawings Please order actuator + separately 23 a (see page 76 5,3 5,3 30 ±0,1 +1 ...

Page 44

Safety Switches with Separate Actuator, Metal Housing Safety switch NZ.VZ Housing according to EN 50041 Protective plate for switch head Plug connector optional LED optional Approach direction Horizontal Can be adjusted in 90°-steps. Protective plate for switch head Makes it ...

Page 45

Safety Switches with Separate Actuator, Metal Housing 3) Plug connector C16-1 6-pin + PE Dimension drawings Please order actuator separately (see page 76 For mating connectors see page 78 Wiring diagrams actuator inserted 538H...C1701 2 4 ...

Page 46

Safety Switches with Separate Actuator, Metal Housing 46 ...

Page 47

Safety Switches with Separate Actuator, Metal Housing Selection table for safety switches NZ.VZ.VS with guard locking Guard locking VSM Mechanical guard locking, closed-circuit current principle VSE Electrical guard locking, open-circuit current principle VSH Manual release Connection Guard locking VSM VSE ...

Page 48

Safety Switches with Separate Actuator, Metal Housing Safety switch NZ.VZ.VSM with guard locking Housing according to EN 50041 Plug connector optional LED optional Approach direction Horizontal Can be adjusted in 90°-steps. Solenoid operating voltage and optional LED function display A ...

Page 49

Safety Switches with Separate Actuator, Metal Housing Plug connector SR6 6-pin + PE Dimension drawings Wiring diagrams 528H 538H ...

Page 50

Safety Switches with Separate Actuator, Metal Housing Safety switch NZ.VZ.VSE with guard locking Housing according to EN 50041 Plug connector optional LED optional Approach direction Horizontal Can be adjusted in 90°-steps. Solenoid operating voltage and optional LED function display A ...

Page 51

Safety Switches with Separate Actuator, Metal Housing Plug connector SR6 6-pin + PE Dimension drawings Wiring diagrams 528H 538H ...

Page 52

Safety Switches with Separate Actuator, Metal Housing Safety switch NZ.VZ.VSH with guard locking Housing according to EN 50041 Manual release Plug connector optional Anfahrrichtung Horizontal Umstellbar in 90°-Schritten. Locking method VSH Mechanical locking by spring force. Ma- nual release. Switching ...

Page 53

Safety Switches with Separate Actuator, Metal Housing Plug connector MR8 7-pin + PE Dimension drawings Wiring diagrams Ordering table Approach Series Connection Actuator Locking direction 1...8C VSH VZ Plug Manual NZ Separate E3 connector guard locking 3 NC actuator MR8 ...

Page 54

Safety Switches with Separate Actuator, Metal Housing 54 ...

Page 55

Safety Switches with Separate Actuator, Metal Housing Selection table for safety switches TZ with guard locking and guard locking monitoring Release feature, front HE Mechanical release can be sealed E Mechanical release cannot be sealed ND Emergency release from the ...

Page 56

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Mechanical release on the front Two LEDs, red and green Plug connector optional Actuating head fitted left or right Mechanical release Is used ...

Page 57

Safety Switches with Separate Actuator, Metal Housing Plug connector SR6 6-pin + PE Dimension drawings actuating head on left is a mirror image Mechanical release 100 ±1 36 ...

Page 58

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Mechanical release on the front Two LEDs, red and green Plug connector Actuating head fitted left or right Mechanical release Is used for ...

Page 59

Safety Switches with Separate Actuator, Metal Housing Plug connector SR11 11-pin + PE Dimension drawings actuating head on left is a mirror image Mechanical release 100 ±1 36 ...

Page 60

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Mechanical release on the front Protective plate for switch head Two LEDs, red and green Plug connector optional Actuating head fitted left or ...

Page 61

Safety Switches with Separate Actuator, Metal Housing Plug connector SR6 6-pin + PE Dimension drawings actuating head on left is a mirror image Mechanical release Wiring diagram actuator inserted and locked SK:528H/ÜK:528H SK:528H 4 13 ...

Page 62

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Emergency release from the front with pushbutton Two LEDs, red and green Plug connector optional Actuating head fitted left or right Emergency release ...

Page 63

Safety Switches with Separate Actuator, Metal Housing Plug connector SR11 11-pin + PE Dimension drawings actuating head on left is a mirror image Emergency release 100 35 91 110 Wiring diagram actuator ...

Page 64

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Emergency unlocking from the front with rotary knob Protective plate for switch head optional Two LEDs, red and green Plug connector Actuating head ...

Page 65

Safety Switches with Separate Actuator, Metal Housing Plug connector RC18 18-pin + PE Dimension drawings actuating head on left is a mirror image Emergency unlocking 100 ±1 36 ...

Page 66

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Mechanical release on the front Escape release from the rear with key button Two LEDs, red and green Plug connector optionall Actuating head ...

Page 67

Safety Switches with Separate Actuator, Metal Housing Plug connector SR11 11-pin + PE Dimension drawings actuating head on left is a mirror image 31 Mechanical release Escape release Wiring diagram actuator inserted and locked ...

Page 68

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Mechanical release on the front Escape release from the rear with pushbutton Two LEDs, red and green Plug connector optional Actuating head fitted ...

Page 69

Safety Switches with Separate Actuator, Metal Housing Plug connector SR11 11-pin + PE Dimension drawings actuating head on left is a mirror image 31 Wiring diagram actuator inserted and locked Ordering table Switch Series Locking Switching element head LE SK: ...

Page 70

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Without mechanical release Protective plate for switch head Two LEDs, red and green Plug connector optional Actuating head fitted left or right Protective ...

Page 71

Safety Switches with Separate Actuator, Metal Housing Plug connector MR12 11-pin + PE Dimension drawings actuating head on left is a mirror image 31 20 Wiring diagram actuator inserted and locked SK:2121H/ÜK:2121H C1902 SK:2121H ÜK:2121H ...

Page 72

Safety Switches with Separate Actuator, Metal Housing Safety switch TZ with guard locking and guard locking monitoring Without mechanical release Two LEDs, red and green Plug connector for switch connection Plug connector for enabling switch Actuating head fitted left or ...

Page 73

Safety Switches with Separate Actuator, Metal Housing Plug connector RC18 and RC12 (enabling switch) 18-pin + PE / 12-pin Dimension drawings actuating head on left is a mirror image Wiring diagram actuator inserted and locked Ordering table ...

Page 74

Safety Switches with Separate Actuator, Metal Housing 74 ...

Page 75

Accessories, Safety Switches Selection table for accessories Actuator Plug connector SS4 Solenoid C16-1 RC12 Plug connector Actuator SS4 Solenoid C16-1 RC12 Plug 3-pin + PE Solenoid plug connector NZ.NZ.VS 2-pin + PE Female connector 6-pin ...

Page 76

Accessories, Safety Switches Actuators for safety switches NZ.VZ, NZ.VZ.VS and TZ Two stainless safety screws per actuator Increased overtravel optional Smaller door radii optional Packaging unit 25 pieces optional Straight actuator The straight actuator is used on sliding doors or ...

Page 77

Accessories, Safety Switches Selection table for actuators Actuator Actuator straight Z-G 016 849 overtravel 4 mm Actuator straight Z-GN 072 251 overtravel 16 mm Hinged actuator Z-L 024 298 Hinged actuator Z-R 024 299 Hinged actuator Z-U 048 850 Hinged ...

Page 78

Accessories, Safety Switches Plug connectors SS4, C16-1, RC12 and solenoid plugs For safety switches series NZ Plug SS4 and TZ 3-pin + PE Plugs and sockets Dimension drawings Blanking plug Solenoid plug Blanking plug To cover the socket for the ...

Page 79

Accessories, Safety Switches Plug connectors SR6 and SR11 For safety switches series NZ Female connector SR6 EF and TZ 6-pin + PE Plugs and sockets Dimension drawings Crimp contacts 90° angled optional Cable optional Coding shells Angled plug connector On ...

Page 80

Accessories, Safety Switches Plug connector RC18 For safety switches TZ 90° angled optional Cable optional Halogen-free cable optional Crimp contacts For wire cross-section 0.75 - 1.00 mm². Option C1825 With 16 crimp pins for wire cross-section 0.38 - 0.5 mm² ...

Page 81

Accessories, Safety Switches Female connector RC18 / RC18..C1825 with cable 18-pin + PE Dimension drawings 78 inserted 71 SW20 Female connector RC18 / RC18..C1825 with cable halogen-free 18-pin + PE 92 inserted 85 Pin assignment plug RC18 with cable and ...

Page 82

Accessories, Safety Switches Plug connectors SGLF and SWLF with cable For safety switches series NZ and N1A Plug connector M12 with cable 90° angled optional Cable Cable sleeve PUR, color black, halogen-free, flame retardant. Reduction of toxic gases and smoke ...

Page 83

Accessories, Safety Switches Mounting plates EMP for safety switches TZ Vertical and horizontal mounting of safety switch TZ The mounting plates are used for fastening safety switches TZ and actuators to safety guards. The safety switches can be attached horizontally ...

Page 84

Accessories, Safety Switches Miscellaneous accessories Lockout bar Protective plate Replacement head for NZ..VZ Lead seal kit LED function display Safety screws Lockout bar With the safety door open, can be slid into the actuating head on a switch with separate ...

Page 85

Accessories, Safety Switches Miscellaneous accessories LED function display LED function display Upgrade kits with LEDs are available for the safety switches N1A and NZ. The intensity of the light from the indicators is always the same independent of the voltage ...

Page 86

Accessories, Safety Switches List of plug connector suppliers We provide no guarantee for the completeness and correctness of the ordering data given. The data was valid in October 2004. The related manufacturers reserve the right to make changes without notice. ...

Page 87

Technical Data Overview Safety switch series N1A Precision single limit switch NB01 Single hole fixing limit switch, small design NZ Position switch NZ NZ.VZ Safety switch NZ.VZ NZ.VZ.VS Safety switch NZ.VZ.VS TZ Safety switch TZ Safety switch series N1A NB01 ...

Page 88

... Utilization category according to IEC 60947-5-1 1) The approach speed given applies in conjunction with EUCHNER trip dogs at an approach angle of 30° smaller approach angle this approach speed can be exceeded. 2) Screwed tight with the related plug connector (see page 82) ...

Page 89

Technical Data Travel diagram N1AD/N1AR/N1AW N1AD Travel diagram N1ARL N1ARL N1AR N1AW Contacts closed Contacts closed 514 508 5 Contacts Contacts positively driven open 514 508 ...

Page 90

... Short circuit protection according to IEC 60269-1 (control circuit fuse) Utilization category according to IEC 60947-5-1 1) The approach speed given applies in conjunction with EUCHNER trip dogs at an approach angle of 30° smaller approach angle this approach speed can be exceeded. Travel diagram NB01D/NB01R NB01D ...

Page 91

... Utilization category according to IEC 60947-5-1 1) The approach speed given applies in conjunction with EUCHNER trip dogs at an approach angle of 30° smaller approach angle this approach speed can be exceeded. 2) Screwed tight with the related plug connector (see page 82) The technical data on switches and switching elements apply to all connection types ...

Page 92

Technical Data Connection, plug connector SR6 Parameters Connection Version Degree of protection according to IEC 60529 Rated insulation voltage U i Conventional thermal current I th Short circuit protection according to IEC 60269-1 (control circuit fuse) Utilization category according to ...

Page 93

Technical Data Travel diagram NZ.WO/NZ.RK NZ...WO NZ...RK Travel diagram NZ.RS/NZ.RG NZ.RS NZ...RG Travel diagram NZ.RL NZ...RL 511 528H 538H 2121H 2 ...

Page 94

Technical Data Travel diagram NZ.HS/NZ.HB NZ...HS NZ...HB 0° Travel diagram NZ.PS/NZ.PB NZ...PS NZ...PB 0° 94 511 528H 538H 0° 0° 0° 0° 10° 10° 10° 10° 20° 20° 20° 20° ° ° ° 30° 30° 30° 30° ...

Page 95

Technical Data Safety switch NZ.VZ Switch Parameters Housing material Mechanical life Ambient temperature Weight Approach speed, max. Approach speed, min Actuating / extraction force min. Retention force Switching element Parameters Switching principle Switching elements With 2 contact elements Switching elements ...

Page 96

Technical Data Connection, plug connector C16-1 Parameters Connection Version Degree of protection according to IEC 60529 Rated insulation voltage U i Conventional thermal current I th Short circuit protection according to IEC 60269-1 (control circuit fuse) Utilization category according to ...

Page 97

Technical Data Safety switches NZ.VZ.VS... with guard locking Switch Parameters Housing material Mechanical life Ambient temperature Weight Approach speed, max. Approach speed, min. Actuating / extraction force min. Locking force max. (guard locking in locked position) Retention force Switching element ...

Page 98

Technical Data Connection, plug connector SR6 Parameters Connection Version Degree of protection according to IEC 60529 Rated insulation voltage U i Conventional thermal current I th Short circuit protection according to IEC 60269-1 (control circuit fuse) Utilization category according to ...

Page 99

Technical Data Safety switch TZ with guard locking and guard locking monitoring Switch Parameters Housing material Mechanical life Ambient temperature Weight Approach speed, max. Actuating / extraction force min. Retention force Locking force max. (guard locking in locked position) Switching ...

Page 100

Technical Data Connection, plug connector MR8 Parameters Connection Version Degree of protection according to IEC 60529 Rated insulation voltage U i Conventional thermal current I th Short circuit protection according to IEC 60269-1 (control circuit fuse) Utilization category according to ...

Page 101

Technical Data Accessories, safety switches Solenoid plug Parameters Housing material Number of pins Nominal voltage max. Degree of protection according to IEC 60529 (inserted) Connection SS4 Parameters Housing material Number of pins Cable diameter Nominal voltage max. Degree of protection ...

Page 102

Technical Data 102 ...

Page 103

Appendix Safety precautions Safety switches perform a personal protection function. Incorrect installation or tampering can lead to severe injuries to personnel. Prior to installation, use and maintenance imperative that you read the operating instructions. Also take into account ...

Page 104

Appendix Overview of the most important standards on machinery safety Type A standards (EN 292-1) ISO 12100-1 Safety of machinery. Basic concepts, general principles for design. Part 1: Basic terminology, methodology withdrawn (EN 292-2) ISO 12100-2 Safety of machinery. ...

Page 105

Appendix EN 848-2 Safety of woodworking machines. One side moulding machines with rotating tool. Part 2: Single spindle handfed/integrated fed routing machines EN 848-3 Safety of woodworking machines. One side moulding machines with rotating tool. Part 3: Numerical control (NC) ...

Page 106

Appendix 29 CFR 1926.304 Woodworking Tools 29 CFR 1926.307 Mechanical Power –Transmission Apparatus 29 CFR 1926.555 Conveyors ANSI standards ANSI B5.37-1970 External Cylindrical Grinding Machines - Centerless ANSI B5.42-198 External Cylindrical Grinding Machines – Universal ANSI B5.52M-1980 Presses, General Purpose, ...

Page 107

Appendix Glossary Actuating force The actuating force is the minimum force required to perform a switching operation. Actuation (electrical / mechanical) Transition of a moving contact from one switch position to another. This will result in a change to the ...

Page 108

Appendix Danger area Any area in or around a machine in which a person is subject to a risk of injury or a health hazard. The hazard can Either be present continuously on the correct use of the machine (movement ...

Page 109

Appendix Hinged actuator The hinged actuator is, unlike the straight actuator, spring mounted and as a result the actuator can be inserted in the actuator head without problems even with small door radii. With larger radii, a straight actuator can ...

Page 110

Appendix Symbol for a positively driven contact Protective plate For switches with separate actuator, a protective plate is available as an option; this plate makes it more difficult to tamper with the actuating head. Protective plate on safety switch without ...

Page 111

... Stan- dards specify the requirements of the directive in more detail and as a rule represent the general state-of-the-art . Manufacturers of safety switches must comply with EN 60947 5. All EUCHNER safety switches comply with this standard. Start (automatic or manual) An item of safety switchgear (e ...

Page 112

Appendix With safety function and with separate actuator (switches) Safety switches are divided into two different functional types. On switches with safety function the actuator is permanently connected to the switch, on switches with separate actuator, the actuator is separate ...

Page 113

... NZ1HB-528-MC569 045 582 85 NZ1HB-538L060-M 048 257 84 NZ1HB-538-M 087 256 84 NZ1HB-538-MC569 091 305 84 NZ1HS-2121-M 046 730 84 NZ1HS-2131-9C-GMMF 086 538 84 NZ1HS-2131-M 075 530 84 NZ1HS-3131-8C-Ford / PT60577-101K01 075 531 84 NZ1HS-3131-9C-GMMF 073 455 84 NZ1HS-3131-M 073 456 84 NZ1HS-3131-M-EX 073 457 84 NZ1HS-511L060GE-M 087 245 16 NZ1HS-511L060-M 087 247 ...

Page 114

Item Index Item NZ1RG-2131-M NZ1RG-3131-M NZ1RG-511L060-M NZ1RG-511L220-M NZ1RG-511-M NZ1RG-528L060-M NZ1RG-528-M NZ1RG-538L060-M NZ1RG-538-M NZ1RK-2131-M NZ1RK-3131-M NZ1RK-511L060-M NZ1RK-511L220-M NZ1RK-511-M NZ1RK-528L060GE-MC1912 NZ1RK-528L060-M NZ1RK-528-M NZ1RK-528-MC1912 NZ1RK-538-M NZ1RL-2131-M NZ1RL-3131-M NZ1RL-511L060-M NZ1RL-511L110-M NZ1RL-511L220-M NZ1RL-511-M NZ1RL-528L060-M NZ1RL-528L220-M NZ1RL-528-M NZ1RL-538L060-M NZ1RL-538-M NZ1RS-2121-M NZ1RS-2131-9C-GMMF NZ1RS-2131-M NZ1RS-3131-9C-GMMF NZ1RS-3131-M NZ1RS-3131-M-EX NZ1RS-511L060GE-M ...

Page 115

Item Index Item NZ1WO-528-M NZ1WO-538L060-M NZ1WO-538-M NZ2HB-2131 NZ2HB-3131 NZ2HB-511 NZ2HB-511L060 NZ2HB-511L060C1630 NZ2HB-511L060C1631 NZ2HB-511L060GE NZ2HB-511SVM5 NZ2HB-528 NZ2HB-528L060 NZ2HB-528L060C1630 NZ2HB-528L060C1631 NZ2HB-528L060GE NZ2HB-528L220 NZ2HB-528SVM5 NZ2HB-538 NZ2HB-538L060 NZ2HB-538SVM5 NZ2HS-2121 NZ2HS-2131 NZ2HS-3131 NZ2HS-511 NZ2HS-511L060 NZ2HS-511L060C1630 NZ2HS-511L060GE NZ2HS-511SVM5 NZ2HS-528 NZ2HS-528L060 NZ2HS-528SVM5 NZ2HS-538 NZ2HS-538L060 NZ2HS-538SVM5 NZ2PS-2121 NZ2PS-2131 ...

Page 116

Item Index Item NZ2WO-511L060 NZ2WO-511L060C1630 NZ2WO-511L060C1631 NZ2WO-511SVM5 NZ2WO-528 NZ2WO-528L060 NZ2WO-528SVM5 NZ2WO-538 NZ2WO-538L060 NZ2WO-538SVM5 Plug connector / AC Plug connector / DC Protective plate NZ/TZ RC-12P1N8A8096 RC-12P1N8A8300 RC187WF-C1825 RC18EF RC18EF1,5M-C1825 RC18EF1,5MF-C1825 RC18EF10M-C1825 RC18EF10MF-C1825 RC18EF15M-C1825 RC18EF15MF-C1825 RC18EF20M-C1825 RC18EF20MF-C1825 RC18EF25M-C1825 RC18EF25MF-C1825 RC18EF3M-C1825 RC18EF3MF-C1825 ...

Page 117

Item Index Item TZ1LE024SR6-C1638 TZ1LE024SR6-C1662 TZ1LE024SR6-C1677 TZ1LE110M TZ1LE110M-C1684 TZ1LE110M-R TZ1LE110MVAB TZ1LE110MVAB-C1623 TZ1LE110MVAB-C1828 TZ1LE110PG0R8C TZ1LE110SR6 TZ1LE220M TZ1LE220M-C1684 TZ1LE220MVAB TZ1LE220SR6 TZ1RE024BHA-C1902 TZ1RE024BHA-C1903 TZ1RE024BHAVFG-RC1924 TZ1RE024BHAVFG-RC1971 TZ1RE024M TZ1RE024M-089471 TZ1RE024M-C1623 TZ1RE024M-C1684 TZ1RE024M-C1815 TZ1RE024M-R TZ1RE024MVAB TZ1RE024MVAB-C1623 TZ1RE024MVAB-C1684 TZ1RE024MVAB-C1828 TZ1RE024MVAB-R TZ1RE024MVFG-RC1925 TZ1RE024PGOR8C TZ1RE024RC18VAB-092999 TZ1RE024RC18VAB-093863 TZ1RE024RC18VAB-C1803 TZ1RE024RC18VAB-C1823 TZ1RE024RC18VAB-C1826 ...

Page 118

... ACTUATOR-Z-GN 43 073 293 RC-12P1N8A8300 85 073 294 RC-12P1N8A8096 85 073 455 M5X10/V100 85 073 456 M5X16/V100 49 073 457 M5X25/V100 57 073 508 NZ1HS-3131-9C-GMMF 57 074 260 TZ1LE024RC18VAB-C1937 57 074 261 TZ1RE024RC18VAB-C1937 57 074 411 ACTUATOR-Z-G/V25 57 074 412 HINGED ACTUATOR-Z-R/V25 84 074 413 HINGED ACTUATOR-Z-L/V25 51 074 414 HINGED ACTUATOR-Z-U/V25 ...

Page 119

... NZ1RK-528L060GE-MC1912 58 086 413 NZ1RS-528L060-M 58 086 525 NZ1HB-511L060GE-M 58 086 527 NZ1HB-528L060GE-M 58 086 528 NZ1RS-511L060GE-M 42 086 538 Lockout bar Z 42 086 574 NZ1HS-3131-8C-Ford / PT60577-101K01 42 087 074 NZ1RS-3131-9C-GMMF 42 087 147 N1ARL508-M 48 087 158 N1AR514AM-M 48 087 180 SR6AM2-M20 50 087 193 N1AD508-MC1292 48 087 197 N1AD508-MC1293 ...

Page 120

Item Index Order No. Item 087 226 N1AW508LE220-M 087 245 N1AB508-M 087 247 N1AB514-M 087 256 Lead seal kit TZ-C1937 087 290 TZ2LE024MVAB-C1828 087 291 TZ2RE024MVAB-C1828 087 558 NZ2WO-538L060 087 595 NZ1RS-2121-M 087 603 N1AD514SVM5-M 087 604 N1AR514SVM5-M 087 990 ...

Page 121

... NZ1HS-511L060GE-M 090 039 NZ1HB-511L060-M 090 040 NZ1HB-511L220-M 090 049 NZ1HS-528L060GE-M 090 050 NZ1HS-528L110-M 090 051 NZ1HB-528L220-M 090 052 NZ1HS-528L220-M 090 136 NZ2HB-2131 090 137 NZ2HB-3131 090 143 NZ2VZ-538E 090 144 NZ2VZ-2131E 090 145 NZ2VZ-3131E 090 146 NZ2HS-2131 090 147 ...

Page 122

... NZ1HB-538L060-M 090 968 NZ1HB-2131-M 090 969 NZ1HB-3131-M 090 970 NZ1HS-528-M 090 971 NZ1HS-528L060-M 090 972 NZ1HS-538-M 090 973 NZ1HS-2131-M 090 974 NZ2RS-2121 090 975 NZ2RL-2121 090 976 NZ2WO-2121 091 062 TZ1LE024RC18VAB-C1803 091 063 TZ1RE024RC18VAB-C1803 091 091 NZ1HB-511L060-MC569 091 261 ...

Page 123

For your notes 123 ...

Page 124

For your notes 124 ...

Page 125

Product Catalog Automation Position Switches Position Switches Position Switches according 041 Precision Multiple Limit Switches Inductive Limit Switches Plug Connectors Trip Rails/Trip Dogs Inductive Ident Systems Safety Safety Switches, Metal Housing Safety Switches Safety ...

Page 126

... Hong Kong Tel. +01-519-966-3444 Tel. +852-2889-0292 Fax +01-519-966-6160 Fax +852-2889-1814 sales@iacnassociates.com info@imperial-elec.com China Hungary EUCHNER Electric (Shanghai) Ltd. EUCHNER Ges.mbH No. 8 High Technology Zone Magyarországi Fióktelep No. 503 Meinengda Road 2045 Törökbálint Songjiang, Shanghai, 201613 Tópark utca 1/a. Tel. +86-(0)21-5774-7090 Tel ...

Page 127

... offic d offic offic d offic offic EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Germany Tel. +49-(0)711-7597-0 Fax +49-(0)711-753316 info@euchner.de www.euchner.de www www euc www euc euc hner hner hner om om www www euc euchner hner om om More than safety. More than safety. More than safety. Mor than safety ...

Related keywords