CES-A-BBA EUCHNER, CES-A-BBA Datasheet - Page 27

ACTUATOR

CES-A-BBA

Manufacturer Part Number
CES-A-BBA
Description
ACTUATOR
Manufacturer
EUCHNER
Datasheet

Specifications of CES-A-BBA

External Depth
40.5mm
External Length / Height
131mm
Operating Temperature Max
55°C
Operating Temperature Min
-0°C
Non-Contact Safety Switches CES/CEM
Ordering table
Subject to technical modifications; no responsibility is accepted for the accuracy of this information.
Technical data
1) Values at a switching current of 50 mA without taking into account the cable lengths.
2) Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator.
3) The fault detection time is the time for the detection of an internal fault in the device. At least one of the semiconductor outputs is switched off safely.
4) After the operating voltage is switched on, the semiconductor outputs are switched off and the monitoring outputs are set LOW during the ready delay.
5) The dwell time of an actuator inside and outside the operating distance must be at least 0.5 s to ensure reliable detection of internal faults in the evaluation unit (self-monitoring).
6) The values apply for surface installation of the actuator.
Series
CES-A-C5...
Parameters
Housing material
Dimensions
Weight
Ambient temperature at U
Degree of protection to IEC/EN 60529
Safety class according to IEC/EN 61558
Installation position
Connection type
Operating voltage U
regulated, residual ripple < 5 %)
For the approval according to
Current consumption
Switching load according to
External fuse (operating voltage)
Power supply for load U(+LA) / U(+LB)
Safety outputs (LA / LB, 2 semiconductor
outputs, p-switching, short circuit-proof,
electrically decoupled)
- Output voltage U(LA) / U(LB)
Switching current per safety output
External fuse U(+LA) / U(+LB),
Safety circuit
Utilization category according to IEC/EN 60947-5-2
Classification according to IEC/EN 60947-5-3
Door monitoring contact (OUT, semiconductor output,
p-switching, short circuit-proof)
- Output voltage
- Max load
Rated insulation voltage U
Rated impulse withstand voltage U
Resilience to vibration
Switching delay from state change
Fault detection time
Difference time between the two safety outputs
Ready delay
Dwell time
Switching frequency
Operating distance for center offset = 0
Switch-on distance s
Switching hysteresis
Safe switch-off distance s
Mounting distance between two read heads
or two actuators
EMC protection requirements
LED indicators
HIGH
HIGH
LOW
U(LA)
U(LB)
U(LA) / U(LB)
5)
4)
B
(reverse polarity protected,
3)
a0
Switch-on distance s
ar
B
i
= DC 24 V
1)
the following applies
imp
2)
20
6)
a0
[mm]
STATE
OUT/ERROR
OUT/ERROR
U(+LA) - 1.5
U(+LB) - 1.5
0.8 x U
M12 plug connector, 8-pin, screen can be applied
0.25
min.
0.5
-20
Safety category
18
18
80
18
0
1
2
Operation with UL-class 2 power supply only
-
-
-
-
-
-
-
-
B
According to IEC/EN 60947-5-2
3
4
According to EN 60 947-5-2
400 mA medium slow-blow
As per IEC/EN 60947-5-3
green LED:
yellow LED:
red LED:
flashing:
Plastic PBT V0 GF30
DC-13 24V 400 mA
DC 24 V, class 2
PDF-M
Value
IP67
typ.
Any
0.4
24
80
20
III
3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Normal operation
Teach-in operation
Actuator detected
- Test input activated
- Internal electronics fault
- Invalid teach-in operation
CES-A-C5H-01
CES-A-C5E-01
Item
U(+LA)
U(+LB)
max.
+55
400
180
500
120
1.5
27
27
20
30
40
U
8
1
3
1
-
-
-
-
B
Order No.
077 750
091 458
V DC
V DC
V DC
V DC
Unit
mm
mm
mA
mA
mA
ms
ms
ms
Hz
kg
°C
kV
A
V
s
s
27