Testing Your Reference Test Cords and
Launch Fiber
You should test your reference test cords and launch fiber
before each job. Use another set of known-good cords to
set a reference and run an Autotest on each patch cord and
launch fiber. Use Smart Remote mode to test two cords at a
time, or Loopback mode to test one cord.
You should also use a fiber microscope, such as the
FiberInspector video probe, to inspect the reference test
cord and launch fiber connectors for damage at least once a
day.
General Test Settings
The following sections describe settings you will usually
need to make before running a test:
You may also want to change the index of refraction if you
do not want to use default values.
Test mode
Fiber type
Test limit
Job settings
Testing Your Reference Test Cords and Launch Fiber
Information on settings specific to a particular test is
provided in the chapter for that test. For information on
setting user preferences, see Chapter 1.
To copy settings between testers, see page 12-5.
Selecting a Test Mode
The test mode determines what type of test will run when
you press
corner of the HOME screen. To change the test mode, press
A
Selecting a Fiber Type
To select a fiber type, press
on the Cable tab.The list shows the last 10 fiber types used.
To see additional fibers, press
GROUP.
The selected fiber type determines which test limits are
available, the default index of refraction, and other values
used for testing.
Select a fiber type before selecting a test limit. The
fiber type determines which test limits are
available.
Change Test; then select a test from the menu.
T
. The mode is shown in the upper-left
Getting Started Testing Fiber
Note
S
B
; then select FIBER TYPE
More; then select a FIBER
2
2-5