Numeral Display
Display Attributes And Drawing Result
Direct Reference and Indirect Reference
Direct reference is a method whereby the memory table whose contents are to
be displayed is specified directly.
In indirect reference, the numeral memory table whose contents are to be dis-
played is not specified directly: the contents of the specified numeral memory
table (a numeric value) are regarded as the number of a numeral memory table,
and the contents of this numeral memory table are displayed. Note that more
processing time is required for indirect reference that for direct reference.
Number of Digits Displayed
All contents of numeral memory tables are stored as integers. To display a nu-
meric value that has a decimal fraction, set the decimal setting to 1 or higher to
specify the number of places after the decimal point, then a decimal point is auto-
matically inserted.
Note that if the number of digits of the numeric value is greater than the total of
the settings for Integer and Decimal, an error occurs and ∗ is displayed for all the
digits.
An example is given below (here, the check mark is assumed to be set for Zero
Suppression).
Example: Displaying 123456
Standard
Flash
Inverse Flash
• Setting for Integer =
Resulting display: 00123456
Attribute
0 0 6 2
7 7 7 7
PT
PT
The numeral display is displayed with the specified foreground
color and background color.
Repeated alternation of the standard display and no display.
Repeated exchange of the foreground color and background
color.
12345678
12345678
Direct
reference
Indirect
reference
Numeral memory
table No. 18
Numeral memory
table No. 18
Numeral memory
table No. 62
0 0 6 2
0 0 6 2
7 7 7 7
8; setting for Decimal = 0:
12345678
Drawing Result
⇔
⇔
PC
Allocated word
(numeral memory table No. 18)
PC
DM0100
Allocated word
(numeral memory table No. 18)
Allocated word
(numeral memory table No. 62)
DM0100
DM0200
0 0 6 2
12345678
0 0 6 2
7 7 7 7
Section
133
2-8
Related parts for NT30-KBA04
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
CHEMICAL RESISTANT COVER FOR NT31
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: