Changing Numerals/Character Strings by Pressing a Touch Switch Which Has the
Copy Setting Function
Changing Numeral and Character String Display
1, 2, 3...
PC Program
Make a PC ladder program as shown below.
Program Operation
This method allows an operator to change the contents of a memory table simply
by operation at the PT. It is also possible to copy data to a numeral setting/char-
acter string input field by using this method. With the Copy Setting function, data
can only be copied in accordance with the predetermined method.
Error flag
Error flag
1. If an error occurs (bit 09000 goes ON), the display on the PT changes to
2. When the error is eliminated (bit 09000 goes OFF), the display on the PT
TIM001
TIM002
09000
09000
FAULT.
returns to NORMAL.
@ANDW(34)
@ANDW(34)
@MOV(21)
@MOV(21)
@ORW(35)
@MOV(21)
@MOV(21)
@ORW(35)
#FFF7
#FFF7
#0004
#0010
#0008
#0004
#0011
#0008
102
101
103
103
102
101
103
103
103
103
103
103
Copy destination memory table No.
Copy destination word
Copy source memory table No.
Copy source word
Copy type, memory table copy execution bit
Word of PT status control bits
Memory table copy execution bit set from 1 to 0
Copy type, copy destination memory table No.
Copy destination word
Copy source memory table No.
Copy source word
Copy type, memory table copy execution bit
Word of PT status control bits
Memory table copy execution bit set from 1 to 0
TIM
001
TIM
002
#0010
(1.0S)
#0010
(1.0S)
Section
(1)
(2)
315