NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 261

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
252
Device Monitor Function
Reference: For details on displaying and using the System Menu, refer to System Menu Op -
Reference: When a Device Monitor screen was displayed while the PT is operating and the
1, 2, 3...
erations in section 6 of the Setup Manual .
PT was then switched to another screen (other than system screens), the PT will
skip the Device Monitor screen when you attempt to return to the previous screen
by pressing the return to previous screen touch switch.
Calling from the System Menu
Calling from a Screen Display during Operation
When calling the Device Monitor function during PT operation, one of the follow-
ing 3 screens can be displayed with a PT status control area operation or the
screen switching function of a touch switch, bit memory table, or alarm list/histo-
ry function.
Refer to the description of each screen switching function for more details on
switching screens.
Differences in the PT Operating Status
The PT’s operating status is different depending on the method used to start the
Device Monitor function.
• Device Monitor Called from the System Menu
• Device Monitor Called by Screen Number
1. Select Expansion Mode → Device Monitor function from the System Menu.
2. Select the desired Device Monitor screen. The selected screen will be dis-
The Device Monitor Menu will be displayed. (The following example shows
the menu of an NT631/NT631C.)
played.
Registration monitor screen:
Continuous monitor screen:
Error Log screen:
The PT will remain stopped, so the following functions will not operate:
• Controlling the PT through the PT status control area
• Notifying the PT through the PT status notify area
• Controlling windows through the window control area
• Monitoring bit memory tables (screen switching and alarm functions)
• Executing calculations with the mathematical table
• Trend graph background and data logging functions
The PT will continue operating, but the following function will not operate:
• Controlling windows through the window control area
(Notifications from the PT cannot be performed either.)
Screen number 9021
Screen number 9022
Screen number 9023
Section
2-17

Related parts for NT30-KBA04