NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 166

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Graphs
*1: When making the setting, ensure that the total of the Start Table Entry and No. of
*2: The –100% value, 0% value, and 100% value must comply with the following
Settings (properties of each broken line)
Points does not exceed the maximum table entry.
relationship:
Start Table
Entry
No. of points
Interval Type
Line
100%
0%
–100%
Color
Style
Table Entry
Value
Table Entry
Value
Table Entry
Value
*2
*1
(Specify 0% value using either of Table Entry or Value.)
*2
*2
(Specify 100% value using either of Table Entry or Value.)
(Specify –100% value using either of Table Entry or Value.)
*1
–100% value < 0% value < 100% value
First numeral memory table number of the numeral memory
tables used to display the broken line.
Number of vertices in the broken line display (one memory table
is used for each vertex)
Interval between numeral memory tables in the broken line.
Display color of the broken line (Colors other than black and
white are available with the NT31C and NT631C only.)
Line type used for the broken line graph
Numeral memory table number checked to find the 100%
value for percentage calculations
@ Designate the number of the numeral memory table that
Checked to find the 100% value for percentage calculations
@ Designate the 100% value (default: 100)
Numeral memory table number checked to find the 0% value
for percentage calculations
@ Designate the number of the numeral memory table that
Checked to find the 0% value for percentage calculations
@ Designate the 0% value (default: 0)
Numeral memory table number checked to find the –100%
value for percentage calculations
@ Designate the number of the numeral memory table that
Checked to find the –100% value for percentage calculations
@ Designate the –100% value (default: –100)
Range: 0 to 1998
NT31/NT31C:
NT631/NT631C: 2 to 512
Even/Uneven (cannot resize) (0 to size in the broken line
graph Direction – 1)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
Solid line:
Broken line:
1-dot chain line:
2-dot chain line:
stores the 100% value.
Range: 0 to 1999
Range: –2147483648 to 2147483647
stores the 0% value.
Range: 0 to 1999
Range: –2147483648 to 2147483647
stores the –100% value.
Range: 0 to 1999
Range: –2147483648 to 2147483647
2 to 320
Section
2-10
157

Related parts for NT30-KBA04