NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 293

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Setting
Operation
Controlling the Backlight Status by the Operation at the PT Status Control Area
3-2-4 Turning off the Screen
284
Buzzer, Backlight, and Display Control
15
14
13
12
11
10
0
9
8
7
6
5
Using this method, the backlight status (lit/flashing) can be controlled at any re-
quired time.
The PT status control area must be allocated to a word in the host, accordingly,
no special settings are required for the control of buzzer.
The bit for controlling the PT status (PT status control bit) is provided at the fourth
word (n + 3 words) from the beginning of the PT status control area.
To control the backlight status during the operation of the PT, operate the PT sta-
tus control area as indicated below.
Set 0 (OFF) or 1 (ON) for bit 8 in the fourth word (n + 3 words) from the beginning
of the PT status control area.
• To turn the backlight on: 0 (OFF) 1 (ON)
• To flash the backlight:
By turning off the screen while it is not in use, the backlight lasts for a long time
and, at the same time, afterimage on the display panel can be prevented. The
backlight is turned off automatically when the screen is turned off. If the screen
saver function is set to Display, however, it is not possible to prolong the life of the
backlight since it is not turned off when the screen is turned off.
The PT provides the following two methods for turning off the screen.
4
Backlight is flashing
Word n + 3, bit 8
3
2
1
0
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bits 2 and 3 are not used when the PT is in NT30/620
compatible mode.
PT
Screen display
Processing priority registration (for NT link (1:N))
Continuous buzzer
Intermittent buzzer (short)
Display history initialization
Not used
Intermittent buzzer (long)
Backlight mode
Screen printing
PT window opening
Numeral/character string input
PT screen switching
Memory table copy execution
Memory table copy type
Alarm history initialization
Not used
1 (ON) 0 (OFF)
Controlled Item
PT status control area
Screen switch setting
Copy memory
table setting
PT status control setting
Reserved for system use
PC
Registered
Performed
Performed
Performed
Performed
Performed
Sounded
Sounded
Sounded
Disabled
Disabled
Disabled
Numeral
1 (ON)
Lit
Section
← Control data
Always 0
Always 0
Character string
Not performed
Not performed
Not performed
Not performed
Not performed
Canceled
Stopped
Stopped
Stopped
Flashing
Enabled
Enabled
Enabled
0 (OFF)
3-2