Operation
3-2
3-2-1 Items to Check Before Turning ON the Power
j Checking Power Supply Voltage
Check to be sure that the power supply voltage is within the ranges shown below.
j Checking Terminal Block Wiring
j Checking the Servomotor Wiring
j Checking Encoder and Resolver Connectors Wiring
j Checking Control Signal Connector Wiring
3-4
Power supply inputs (models with single-phase inputs: R and S, models with three-phase inputs: R,
S, T, R0, S0) must be properly connected to the terminal block.
The Servomotor’s red (A/U), white (B/V), and blue/black (C/W) power lines and the green ground
wire ( ) must be properly connected to the terminal block.
There should be no load on the Servomotor. (Do not connect to the mechanical system.)
The power line connectors at the Servomotor must be securely connected.
Encoder and resolver cables must be securely connected to the motor sensor connectors (CN2) at
the Driver.
Encoder and resolver cables must be securely connected to the encoder/resolver connectors at the
Servomotor.
Be sure that the control signal connectors or the CompoBus/S terminals and external control signal
connectors are firmly connected.
The RUN command must be OFF.
FND-X06H- /-X12H- /-X25H-
FND-X50H-
FND-X
Turning ON Power and Checking Displays
L-
(three-phase, 200-VAC specifications):
(single-phase, 100-VAC specifications):
(single-phase, 200-VAC specifications):
Single-phase 200/240 VAC (170 to 264 V) 50/60 Hz
Three-phase 200/240 VAC (170 to 264 V) 50/60 Hz
Single-phase 100/115 VAC (85 to 127 V) 50/60 Hz
Chapter 3