CompoBus/S Specifications
6-3
This manual only explains the CompoBus/S wiring related to FND-X-series Position Drivers. For more
information on connecting communications cables, wiring, Slaves, and so on, refer to the CompoBus/S
Operation Manual (W266) .
j Preparing Communications Cables
When connecting CompoBus/S cable to the Position Driver, follow the procedure shown below to pre-
pare the cable.
j Connecting Communications Cable
Note If the communications cable can be connected by simply tightening the screws, the cable terminal
6-6
1. Remove 5 to 7 mm of the insulation from the end of the communications cable (two wires), and se-
2. When using special flat cable, the two power supply signal wires must be insulated.
1. Use a flat-head screwdriver to loosen the Position Driver’s two CompoBus/S communications ter-
2. Loosen the screws that fasten the signal wires to the cable terminal block, and carefully insert the
curely twist the loose strands together for each of them.
minal screws, and remove the cable terminal block.
two signal wires into their respective holes in the terminal block.
When using commercially-available VCTF cable, determine in advance which signal wire is to be
used for BD H (high) and which for BD L (low).
For special flat cable, the signal wires are as shown below.
block need not be removed.
Connecting a CompoBus/S System
Communications power supply positive side (BS+): Brown
Communications data “high” side (BD H): Black
Communications data “low” side (BD L): White
Communications power supply negative side (BS–): Blue
BD H
5 to 7 mm
BD L
Cable terminal block
Screws
Chapter 6