MT9V022IA7ATM Aptina LLC, MT9V022IA7ATM Datasheet - Page 14

SENSOR IMAGE VGA MONO 52IBGA

MT9V022IA7ATM

Manufacturer Part Number
MT9V022IA7ATM
Description
SENSOR IMAGE VGA MONO 52IBGA
Manufacturer
Aptina LLC
Type
CMOS Imagingr
Series
DigitalClarity®r
Datasheets

Specifications of MT9V022IA7ATM

Pixel Size
6µm x 6µm
Active Pixel Array
752H x 480V
Frames Per Second
60
Voltage - Supply
3.3V
Package / Case
52-IBGA
Sensor Image Color Type
Monochrome
Sensor Image Size Range
250,920 to 480,000Pixels
Sensor Image Size
752x480Pixels
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Operating Temp Range
-40C to 85C
Package Type
IBGA
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
52
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
557-1205

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT9V022IA7ATM-DP
0
Company:
Part Number:
MT9V022IA7ATM-DP
Quantity:
4 500
Table 4:
Table 5:
PDF: 3295348826/Source:7478516499
MT9V022_DS - Rev.H 6/10 EN
Parameter
Parameter
A+Q
V
Nrows x (A + Q)
F
V’
F”
Frame Time (continued)
Frame Time—Long Integration Time
Notes:
Name
Name
Row time
Vertical blanking
Frame valid time
Total frame time
Vertical blanking (long
integration time)
Total frame time (long integration
time)
Sensor timing is shown above in terms of pixel clock and master clock cycles (refer to
Figure 7 on page 13). The recommended master clock frequency is 26.66 MHz. The
vertical blanking and total frame time equations assume that the number of integration
rows (bits 11 through 0 of R0x0B) is less than the number of active rows plus blanking
rows minus overhead rows (R0x03 + R0x06 - 2). If this is not the case, the number of inte-
gration rows must be used instead to determine the frame time, as shown in Table 5. In
this example it is assumed that R0x0B is programmed with 523 rows. For Simultaneous
Mode, if the exposure time register (0x0B) exceeds the total readout time, then vertical
blanking is internally extended automatically to adjust for the additional integration
time required. This extended value is not written back to R0x06 (vertical blanking).
R0x06 can be used to adjust frame to frame readout time. This register does not effect
the exposure time but it may extend the readout time.
1. The MT9V022 uses column parallel analog-digital converters, thus short row timing is not possible. The
minimum total row time is 660 columns (horizontal width + horizontal blanking). The minimum hori-
zontal blanking is 43. When the window width is set below 617, horizontal blanking must be increased.
The frame rate will not increase for row times less than 660 columns.
Equation
(Number of Master Clock Cycles)
(R0x0B + 2 - R0x03) × (A + Q) + 4
(R0x0B + 2) × (A + Q) + 4
Equation
R0x04 + R0x05
(R0x06) x (A + Q) + 4
(R0x03) × (A + Q)
V + (Nrows x (A + Q))
14
MT9V022: 1/3-Inch Wide-VGA Digital Image Sensor
Aptina reserves the right to change products or specifications without notice.
Default Timing at 26.66 MHz
846 pixel clocks
= 846 master
= 31.72μs
38,074 pixel clocks
= 38,074 master
= 1.43ms
406,080 pixel clocks
= 406,080 master
= 15.23ms
444,154 pixel clocks
= 444,154 master
= 16.66ms
Default Timing
at 26.66 MHz
38,074 pixel clocks
= 38,074 master
= 1.43ms
444,154 pixel clocks
= 444,154 master
= 16.66ms
©2005 Aptina Imaging Corporation. All rights reserved.
Output Data Format

Related parts for MT9V022IA7ATM